My-H010 Medical Equipment EEG Machine
My-H010 Medical Equipment EEG Machine

Diagnosis equipment

Performance Parameter
Numbers of channels: 19 channels of EEG+5 channels of multi-parameters (1channel of ECG+ 1channel of EMG+ 2 channels of EOG +1channel of Breath)(multi-parameters are selectable)
Speed of sampling: 200 Hz/sec.
Precision of sampling: 12 bit
Input impedance: ≥ 10MΩ
Patient leak current: < 10uA
Level of noise: ≤ 5UV Vp-p
CMRR: ≥ 90dB
Magnifying multiple: 10 000
Filtering constant: All digital and free enactment
Speed of displaying(paper speed): 5, 10, 15, 30, 60, 120 mm/s
Displaying gain: 1, 2, 5, 10, 12, 15, 20 mm/50UV
Speed of review: 1, 2, 3, 10, 20, 40, 60
50Hz interference suppression ratio: ≥ 30dB
 
Item No. MA88-2400
Item Name  Medical Equipment EEG Machine
Speed of sampling 200 Hz/sec.
Precision of sampling 12 bit
Input impedance ≥ 10MΩ
Patient leak current < 10uA
Level of noise ≤ 5UV Vp-p
CMRR 90dB
Magnifying multiple 10 000



Function Features
1. Standard 24 leads of EEG. Method of 10/20 electrodes placement under international standard system, can change leads ways while real-time playing or replaying. Supporting sorts of lead mode, such as Al, A2, A1+A2, A1A2, BN, CZ, user-defined, and so on.
2. Using bioelectricity amplifier brainwave, consecutive record time can be up to 24 hours, integrated automatic calibration system.
3. Powerful playback function: It is adjustable for the amplitude and replaying rate. The special subdividing time line divides the waveform in one second into 5 parts and easy for the doctors to look over the waveform
4. Multifunctional digital filter system can be set freely and provides many filtering methods.
5. EEG signal clipping function, clipping any a section of EEG wave to analyse and store, clipping multi-section waves to perform multi-parameter analyse and pick-up automatically
6. Electronic frequency ruler, convenient to measure the basic information of any appointed EEG waves. Sectional enlargine window, which can be adjusted by yourself, is provided to increase the accuracy of EEG period /amplitude /frequency measurement
7. Mark event (openning eyes, closing eyes and flashing) EEG with different colors, and name the user-defined event. Color of background and waveform occurred by different event is adjustable. It is able to depend on the event's name to locate speedily the waveform of the corresponding time.
8. Powerful automatic analyse function, can carry through the power spectrum analyse and pathologic wave detection for appointed waveform. Sorts of graph can be displayed in the same screen, including kinds of BEAM, numerical BEAM, compressed spectrum graph, trend graph, and so on.

9. Professional isolation transformer, dual power supply isolation system and optoelectronic data transmission to ensure security. Use USB interface to transmit data which just need to be inserted. Distance of digital signal transmission is up to a maximum of 30 meters. Patients and doctors can be operated in different rooms
10. Multifunctional flashlight of USB interface, and frequency can be controled manually or automatically. A flashlight stimulus scheme can be set and performed in the process of collection.
11. Perfect case management, multi-method of information query and quick statistics means, convenient case input and output function, supporting MO or CD-RW store, which is easy for data research.
12. The report of picture and character integration, can be edited in mode and changed into Word.
13. The case can be transfromed into the EDF data format, which is convenient for the data interchange, academic exchanges and further analyse.
14. System setup function, multi-function, such as display mode, system parameters, etc., can be set to meet the users' special need.
15. Mark positioning function: Add the mark and note for the waveform of appointed time, and locate speedily the waveform at the mark time.


 

Send your message to this supplier

*From:
*To:
avatar Ms. Nancy
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

Diamond Member Since 2012

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
31
Type of Ownership
Limited Company