Patient Monitor, Portable Patient Monitor, Patient Monitoring System manufacturer / supplier in China, offering 12.1 Inch Portable Patient Monitor, My-B022 Elisa Reader, My-D012 100mA Medical X-ray Equipment X Ray Machine and so on.

(/ )

Supplier Homepage Product Patient Monitor and Doppler Detector 12.1 Inch Portable Patient Monitor

12.1 Inch Portable Patient Monitor

FOB Price: US $650-800 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $650-800/ Piece
Get Latest Price
Port: Guangzhou, China
Production Capacity: 100 PCS/Month
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: MY-C005
  • Type: Patient/Fetal/Maternal Monitor
  • Width: 0.1ms ~ 2ms
  • Trademark: MAYA
  • Specification: CE, ISO
  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment
  • Medical Devices Reg./Record No.: Ssyjxzz20062210132
  • Range: 0~100%
  • Transport Package: Carton Box
  • Origin: China
Product Description
MY-C005 12 inch VET patient minitor

Features:
12.1'' screen with true color, wide viewing angle, high brightness LCD display.
HR/PR, NIBP, RR, ECG, SpO2, TEMP
Simple and friendly operating display interface.
Rechargeable lithium battery provides convenience for patients' moving.
Playback and browse function for long term waveform and monitor data record.
Optional printing output function, alarm triggers printing.
Auto double alarm with audible and visible signals
Anti-defibrillation, anti-interference from high frequency electric knife
A full-synchronistic lead multi-channel ECG display...
This medical equipment can be used in ICU, CCU and operation room.
Suitable for adult, pediatrics and neonate patients.

Standard configuration:
HR/PR, NIBP, RR, ECG, SpO2, TEMP, Rechargeable lithium battery
Optional:
Dual TEMP
Dual IBP
ETCO2
Thermal recorder
Wall mount
Trolley

Specification:
ECG
Lead configuration
Standard 3-lead or 5-lead
3-lead RA, LA, LL, Lead method: I, II, III
5-lead RA, LA, LL, RL, V, Lead method: I, II, III, AVR, aVL, aVF, V
Increase
250, 500, 1000, 2000
HR
Range
Adult 15 ~ 300bpm (beat/minute)
Neonatal baby/children 15 ~ 350 bpm(beat/minute)
Precision ± 1% or ± 1bpm, the larger prevails
Resolution 1 bpm(beat/minute)
Sensitivity
> 200 UV (Peak-to-peak value)
Input Impedance
> 5 (megohm)
Bandwidth
Diagnostic mode 0.05~130Hz
Monitoring Mode 0.5~40Hz
Operation mode 1~20Hz
Common Mode rejection Ratio
Diagnostic mode > 90 dB
Monitoring Mode > 100 dB
Operation mode > 100 dB
Pole Polarization Vvoltage Range
300mV
Pacing Pulse Test
Test pacing pulse in accordance with the following conditions:
Amplitude: ± 2 mV ~ ± 700mV
Width: 0.1ms ~ 2ms
Risetime: 10us~100µ S
Pacing pulse inhibition
When pacing analysis switch is on, pacing pulse in accordance with the following conditions are restrained, but affection against HR calculation.
Amplitude: ± 2 mV ~ ± 700mV
Width: 0.1ms ~ 2ms
Risetime: 10us ~ 100µ S
Baseline Recovering Time
After defibrillation< 3 seconds
Signal Range
8 mV (Peak-to-peak value)
Calibrating Signal
1mV(Peak-to-peak value), precision 5%

Range
Adult Systolic blood pressure 40~270mmHg
Diastolic blood pressure 10~215mmHg
Mean blood pressure 20~235mmHg
Children Systolic blood pressure 40~200mmHg
Diastolic blood pressure 10~150mmHg
Mean blood pressure 20~165mmHg
Neonatal baby Systolic blood pressure 40~135mmHg
Diastolic blood pressure 10~100mmHg
Mean blood pressure 20~110mmHg
Static pressure range 0~300mmHg
Static pressure precision 3mmHg
Pressure precision: Max. Average error: 5mmHg; Max. Standard deviation: 8mmHg

Overvoltage protection
Adult mode 300 mmHg
Children mode 240 mmHg
Neonatal baby mode 150 mmHg
SpO2
Range 0~100%
Resolution 1%
Precision 70~100%: 2 DIGIT
0%~69%: No definition given
PR
Range 20~300bpm
Resolution 1bpm
Precision 3bpm
TEMP
Suitable for temperature sensor
YSI series, CYF series

Channel quantity
2 channels
Measuring
Range 0~50C
Resolution 0.1C
Precision 0.1C(excluding sensor error)
IBP
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART 0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP -10 ~ 40 mmHg
P1/P2 -10 ~ 300 mmHg
Press Sensor
Sensitivity 5 UV/V/mmHg
Impedance 300-3000Ω
Resolution 1 mmHg
Accuracy 2% or 1mmHg, which great
Actualization interval about 1 Sec.