Basic Info
  • Model NO.: MY-C002
  • Measurement Display: Color TFT- LCD/Touch Screen
  • Charging Indicator: a Green LED
  • Transport and Storage: -25°c~85°c
  • Transport Package: Carton
  • Medical Devices Reg./Record No.: Ssyjxzz20062210132
  • Power Supply Indicator: Dual-Color LED (Red/Green)
  • Working: 0°c~45°c
  • Trademark: MAYA
  • Origin: China
Product Description

Measuring range

Systolic pressure:

 

Adultt: 40mmH~255mmHg

 

Infant: 40mmHg~200mmHg

 

Mean arterial pressure:

 

Adult:20mmHg~215mmHg

 

Infant: 20mmHg~165mmHg

 

Diastolic pressure:

 

Adult:10mmHg~195mmHg

 

Infant: 10mmHg~150 mmHg

NIBP accuracy

Maximal mean difference: ±5 mmHg
Maximal standard deviation: 8 mmHg

Measurement mode

Manual, Auto, STAT

TEMP Monitoring

Measuring range

25.0ºC~45.0ºC

Measuring accuracy

±0.2ºC

Responding time

≤150s

SpO2 & Pulse Rate Monitoring

Transducer

dual-wave length LED

SpO2 measuring range

35%~100%

Low perfusion capability

0.4%~5%

SpO2 display accuracy

Not greater than 3% for SpO2 range from 70% to 100%

Low perfusion capability

0.4% ~ 5%

PR measuring range

30bpm~240bpm

PR measuring accuracy

±2bpm or ±2%, whichever is greater

ECG Monitoring

Input signals range in amplitude

±(0.4mVp~5mVp)

Heart rate display range

20bpm~300bpm

HR Display accuracy

±1% or ±2bpm, whichever is greater

HR alarm delay time

≤10s

Sensitivity selection

×1/2, ×1, ×2
tolerance: ≤5%

Sweeping speed

12.5mm/s, 25mm/s, 50mm/s
tolerance: ≤10%

ECG noise level

≤30μVP-P

ECG input loop current

≤0.1μA

Input impedance

≥5MΩ

Common-mode rejection ratio

≥89dB

Time constant

Monitoring mode≥0.3s
Diagnostic mode≥3.2s

Frequency response

Monitoring mode: 0.5Hz~40Hz  
Diagnostic modes: 0.05Hz~75Hz

RESP Monitoring

Monitoring range

0rpm~120rpm

Monitoring accuracy

±5% or ±2 rpm, whichever is greater

RESP alarm range

0bpm~120bpm

Alarm tolerance

±5% or ±2 rpm, whichever is greater

Other Technical Specifications

Power supply

100~240VAC, 50/60Hz

Rechargeable Li-ion battery specification

14.8V 2200mAh

Display mode

7 inches TFT color LCD

Resolution

800*480pixel

Alarming mode

Audible & visual alarm

Communication

Serial/Net port

Standard Configuration



Our Advantage :
1: For all your inquires about us or our products , we will reply you in detail within 24 hours.
2: We own professional team have professional attitude to recommend products and services.
3:One year free warranty , after it is still providing after-sales service .
4: We offer OEM services , Can print your own logo on the products .
5:We have very experienced engineers , can help you better use our products .
 
 
Send your message to this supplier
Avatar
Ms. Elaine
Director
*From:
To: Ms. Elaine
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now