• My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System

My-D011 200mA Diagnostic X-ray System

Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Group: All
Max DC Output Current: 200mA
Max DC Output Voltage: 100kv
Moving Range of Bed Surface: 640mm in Length, 200mmin Breadth
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 19 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
MY-D011
Voltage
380V/220V
Transport Package
Wooden Box
Specification
CE
Trademark
MAYA
Origin
China
Production Capacity
500PCS/Month

Product Description

MY-D011 200mA Diagnostic X-ray System
My-D011 200mA Diagnostic X-ray System
Detailed Product Description
1, MA200A 200mA Medical X-ray model
2, Special in radiography
3, tube currency is 200mA

MA200A 200mA Medical X-ray System
USE
General radiography, Filter-ray-filter radiograph

Unit Configuration
Control, HT generator unit, Ht cable, X-ray tube unit, Radiographic table-X-ray source column, Collimator

MAIN CHARACTERISTICS
1, Single-table/single-tube

2, Rotary anode X-ray tube unit and tangential annular tube head

3, Single-phase full wave rectification high-voltage generator

4, Power voltage(v) radiograph kilovolt (KV). Step-less control electric mechanism

5, Filament stabilizer for X-ray tube unit and space charge compel mentor

6, Radiograph volume KV, MA and S. Grading and interlock protection

7, Adopt digital circuit timer. Grading according to R10 priority coefficient, (for more accurately controlling time)

8, HT primary, the zero controlled circuit of silicon-controlled rectifier of heavy power

9, Radiographic table can move in length an breadth

10, The radiographic table. Column and vibrating grid are in a whole without ceiling and floor rails bottom
ITEM CONTENTS INDEX
Demand  of  power  supply Capacity Two-phase  30KVA
Voltage, Frequency 380V/220V      ± 10%50HZ  ± 0.5Hz
    Intemal    resistance 0.752Ω (380V)    0.25Ω (220V)
power  supply Adjustable  range 380± 10%  at220V  being  adjustable  continuously
Radiograph Voltage 50-100KV       
        50-100KV    being    adjustable    continuously
current Small  focus: 50mA100mA, Big  focus: 50mA  100mA    200mA    300mA
time 0.04~6.35s  23grades  together  grading  a  according  to  R10  coefficient
High-voltage  generator Capacity 20KVA(instantaneous)
Max  DC  output  voltage 100KV
Max  DC  output  current 200mA
X-Ray  tube Model XD51.20-40/100
Focus Small  focus  1× 1mm    big  focus2× 2mm
Radiographic  table Length× width× height  of  bed  surface 2000mm× 665mm× 700mm
Moving  range  of  bed  surface 640mm  in  Length, 200mmin  breadth
Ray-filter  of  table Travel  in  length  ≥ 500mm
Grid  density  N=28
Convergence  distance  f. =100cm
Grid  ratio  r=8
Column  of  X-ray  tube  unit Moving  Longitudinally  along
Radiographic  table
1000mm  or  1800mm
Distance  to  friend  as  moving  up  and  down  (along  column) 650~1800mm
Rotary  around  the  center  of  cross  arm ± 180°
Rotary  around  the  shaft  line  of
X-ray  annular  tubes
-10° ~60° ~    +120°
Max  size  of  cassette 356mm× 432mm    (14″ × 17″ )

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now