• Patient Monitor Veterinary Cats Dogs Patient Monitor 12.1-Inch Big Screen Patient Monitor
  • Patient Monitor Veterinary Cats Dogs Patient Monitor 12.1-Inch Big Screen Patient Monitor
  • Patient Monitor Veterinary Cats Dogs Patient Monitor 12.1-Inch Big Screen Patient Monitor
  • Patient Monitor Veterinary Cats Dogs Patient Monitor 12.1-Inch Big Screen Patient Monitor
  • Patient Monitor Veterinary Cats Dogs Patient Monitor 12.1-Inch Big Screen Patient Monitor
  • Patient Monitor Veterinary Cats Dogs Patient Monitor 12.1-Inch Big Screen Patient Monitor

Patient Monitor Veterinary Cats Dogs Patient Monitor 12.1-Inch Big Screen Patient Monitor

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE
Group: All
Transport Package: Carton Box
Specification: CE, ISO
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 19 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
MY-C007
Trademark
Maya
Origin
China
Production Capacity
500 PCS/Year

Product Description

Product Description

 

My-C007 Portable Patient Monitor with Low Price
Patient Monitor Veterinary Cats Dogs Patient Monitor 12.1-Inch Big Screen Patient Monitor

Description:
Standard configuration: ECG, HR, PR, SpO2, OxyCRG diagram, ST analysis, Arrhythmia analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation and lead-acid battery, remote control.

Optional configuration:
Wireless networking function to patient monitor;
Inside placed thermal-sensitive built-in printer;
IBP function (Include 1 pressure sensor and 1 adaptable cable);
ETCO2 function module(Respironics-main stream/side stream)-plug&play;
Cardiac Output
Wall Mount for patient monitor;
Trolly for patient monitor;
12 volts Power supply for ambulance

Accessories for Standard configuration:
1 remote controller
1 set of ECG cable
10 PCS of ECG electrode
1 set of NIBP extend cable
1 set of NIBP adult or pediatric or neonate cuff
1 set of RESP nasal cavity pipe
1 set of TEMP surface probe
1 set of TEMP cavity probe
1 set of integrated adult or pediatric or neonate SpO2 sensor
1 set of power supply cable

E CGInput: 5 wires ECG cable Lead section: I, II, III/ AVR, aVL, aVF/ V Gain(mm/mV): 1/4, 1/2, 1, 2, 4Sweep speed(mm/sec): 6.25, 12.5, 25, 50 Heart rate range: 15-300 BPMHeart rate accuracy: ± 1 %ST segment deviation analysis
NIBP (Non-invasive blood pressure) ()
Measurement type: Adult, pediatric, neonatal Measurement range: Systolic 4.0 - 37.0 kPa Diastolic 1.3 - 33.0 kPa Mean 2.6 - 35.0 kPaAccuracy: ± 0.4 kPa or 5 %Resolution: 0.1 kPaProtection: Over pressure
Tourniquet function

Temperature (surface and rectal)Measurement range: 25.0 - 45.0 CAccuracy: ± 0.1 CResolution: 0.1 Cresponse time: ≤ 3 min.

Respiration Rate(RA-LL, RA-LA, LL-LA selectable impedance and nasal cavity) Measurement range: 0 - 120 BPMAccuracy: ± 1 BPM or 5 %Resolution: 1 BPM
Pulse RateSPO2 measurement range: 0 - 100 %Resolution: 1 %Pulse measurement range: 30- 250BPMAccuracy: ± 2 %Resolution: 1 BPM

IBP(Invasive blood pressure) (Option)Measurement range: -1.3~40kPa (-10~300mmHg) Channel: 4 channelTransducer sensitivity: 5MV/V/mmHg Unit display: KPa or mmHg selectable

ETCO2 (main/side stream type) (Option) - Plug&PlayMeasurement range: 0- 150 mmHg 0 -19.7% 0 - 20kpa
(Barometric pressure supplied by Host)Accuracy: 0- 40 mmHg ± 2mmHg
41-70 mmHg ± 5% of reading
71-100mmHg± 8% of reading
101-150mmHg± 10% of reading
Above 80 breath per minute± 12% of reading
*NOTE: Gas temperature at 25 CSample rate: 50ml/minResponse time: < 3 seconds - includes transport time and rise time

Cardiac Output (Option)
Meathod: Thermodilution
Measurement range: CO: 0.1-20.0 L/min
TB: 23-43 C TI: 0 - 27 C Resolution: CO: 0.1 L/min
TI: 0.1C TB: 0.1C
Accuracy: CO: ± 0.2 L/min or ± 5%
TB: ± 0.2 C TI: ± 0.2CParameter output:
Cardiac output Hemodynamics calculation
Power requirements Input: 100~240 V AC, 50/60Hz Consumption: ≤ 80VA Environment Operation Storage Temperature 0.5 - 40 C -20 - 50 C Relative humidity ≤ 80%
Safety standard: IEC 60601-1
Quality System: ISO13485: 2003

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now