Gold Member Since 2012
Audited Supplier
Guangzhou Maya Medical Equipment Co., Ltd.

Spectrophotomete, UV-Vis Spectrophotometer, UV Vis Spectrophotometer manufacturer / supplier in China, offering My-B050 UV-Visible Spectrophotometer, My-D017 500mA Medical X Ray Unit X-ray Machine, My-D014 Medical Supply 300mA Medical X-ray Machine and so on.

(/ )

Supplier Homepage Product Laboratory Equipment My-B050 UV-Visible Spectrophotometer

My-B050 UV-Visible Spectrophotometer

FOB Price: US $1,990-2,200 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $1,990-2,200/ Piece
Get Latest Price
Production Capacity: 500PCS/Month
Transport Package: Standard Exports Package
Payment Terms: T/T, Money Gram, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: MY-B050
  • Display: 128*64 LCD, Blue Color
  • Wavelength Range: 190-1100 Nm, Autoscan
  • Trademark: Maya
  • Origin: China
  • Model: My-B050
  • Lamp Change Point: Can Be Set, 300 Nm - 400 Nm
  • Wavelength Accuracy: ±1.0 Nm
  • Specification: CE
Product Description
MY-B050 UV-Visible Spectrophotometer
 
All spectrophotometers feature high performance sealed optics mounted on a stable machined platform. The innovative optical layout and state of C-T monochromator with high grade blazed holographic grating ensure accuracy. Its integrated design assures long-term stability and durability. All spectrophotometer are intended to be utilized for research, development, quality control, etc. primarily in the fields of optical materials, semiconductors, new materials, electronics and so on through qualitative and quantitative analyses of samples diverse in kind and size. The comprehensive features, optional sophisticated powerful software, variety of accessories and model configurations will meet or exceed your expectations for performance and value.
 
 
1. Features:
aThe spectrophotometers perform built-in wavelength calibration program automatically after energization. Core components will be check during the initialization to ensure the wavelength accuracy and excellent performance
bPre-aligned deuterium lamp and tungsten lamp for easy lamp replacement. The light source changing point can be set in range of 300nm - 400nm
cThe innovative optical layout ensures accuracy. Its integrated design assures long-term stability and durability. The precisely aligned detector and quality deuterium and halogen lamps enhance the precision.
dPerform basic mode( Abs / %T), quantitative
ePre-set wavelength program (4 wavelengths), and one-touch key response
fSingle-point curve calibration and multi-point curve calibration (up to 12 points)
gDisplay of fitting degree of curve fitting and concentration data with up to 50 sets of curve parameters storage
hDisplay of concentration data with up to 200 sets of data storage
iDark current calibration / wavelength calibration/System clock management
jBackup battery and integrated circuit design controlled by MCU assure non-volatile memory storage
kUSB data communication
lLPT port for printing
m128*64 LCD screen to display all of the parameters
nSealed and solvent-resistant tactile keypad
 
 
2. Technical specifications
ModelMY-B050
MonochromatorC-T type, 1200 L/mm grating
DetectorSilicon detector for ultraviolet visible region
Display128*64 LCD, Blue color
Light sourceDeuterium discharge tube(2000h), Tungsten lamp(2000h, 20W/12V)
Lamp change pointCan be set, 300 nm - 400 nm
Wavelength range190-1100 nm, autoscan
Wavelength accuracy±1.0 nm
Wavelength calibrationAutomatic at start
Wavelength display0.1 nm
Slit width2 nm
Wavelength repeatability0.5 nm
Measurement range-1.0 ~ 200.0%T, -0.5 ~ 3.000Abs, 0 ~ 9999 C, 0 ~ 9999 F
Photometric accuracy±0.002 Abs (0 to 0.5Abs), ±0.004 Abs (0.5 to 1.0 Abs)
Photometric repeatability±0.001 Abs (0 to 0.5Abs), ±0.002 Abs (0.5 to 1.0 Abs)
Stray light0.15 %T (at 220,360 nm)
Baseline flatness±0.004 Abs
Stability≤0.002 Abs / h (at 500 nm, after 2 hours energization)
Data outputDigital, USB port, LPT parallel
Spectrum softwareSpectrum software, Windows® - based
Power220V 10% 50Hz 70VA  /  110V 10% 60Hz 70VA
Standard sample holder4-position sample holder
Actual dimensions456 W X 375 D X 220 H mm, (18.0 W x 14.8 D x 8.7 H in)
Net weight14.5 Kg (32.0 lbs)
Shipping dimensions19.5 Kg (43.0 lbs)
 
3. Features for spectrum software (Optional):
Basic Mode
Multi-Wavelength
Absorbance, %T or Concentration measurements.
Up to 15 wavelengths can be selected and multiple samples can be measured. (Auto cell changer is required to run multiple samples automatically).
Quantitative (Standard Curve)
Use up to 12 standards to establish standard curve.
Four methods for fitting a curve:
a. Linear fit
b. Linear through zero
c. Square fit
d. Segmented

Wavelength Scanning
Interval: 0.1, 0.2, 0.5, 1, 2, 5 nm
Automatically record peaks and valleys.
Post-run manipulation and processing includes:
a. Re-scaling axes, curve
b. Smoothing, combination, zooming, overlap
c. 1st to 3rd derivative
Kinetics (Abs vs. Time)
The Kinetics mode may be used for time course scanning or reaction rate calculations. Abs. vs. time graphs is displayed on the screen in real time. Wait time, measurement time and time intervals may be entered. Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.
DNA/Protein
Concentration and DNA purity can be calculated quickly and easily: Absorbance ratios 230nm/260nm/280nm with optional subtracted absorbance at 320nm.
 