Maya Medical Patient Monitor (MAP002)
Parameters: Δ Δ
Displayer: 8.4" color TFT LCD screen with maximum 7-waveform display. Adjusting of lightness continuously make patient more comfortable in midnightΔ Δ Battery: Rechargeable high-energy built-in batteryΔ Advanced streamline outline design, portable, compact, lightweight Δ Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, French, Arabic, Russian, etc. Δ Easy operation with user friendly menu structure design and rotary dial Δ Against electrosurgical interference and defibrillation and no need to disconnect the monitor from the patient in process of defibrillating. Δ WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possibleΔ
Optional built-in wireless networking function Δ Support external printer to record graph and trendΔ Intelligent audio and visual comprehensive alarmΔ In-hospital applications include emergency pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas. Δ Suitable for use in physicians' offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring
Standard configuration: ECG, HR, PR, SpO2, ST analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation.
Optional configuration: Wireless connection, Recorder and, 2-IBP
Technical Parameter
Temperature (surface and rectal)Measurement range: 25.0 -45.0ºCAccuracy: ± 0.1 ºCResolution: 0.1 ºCresponse time: ≤ 3 min.
ECGInput: 5 wires ECG cable Lead section: I, II, III/ aVR, aVL, aVF/ V Gain(mm/mV): 1/4, 1/2, 1, 2, 4Frequency response: Diagnosis 0.05 - 100Hz Monitor 0.5 - 40 Hz Surgery 1.0 - 25 Hz Sweep speed(mm/sec): 12.5, 25, 50 Heart rate range: 30-254 BPMHeart rate accuracy: ± 1 %ST segment deviation analysis: -0.8-+0.8mVST accuracy: ± 0.02mv
Respiration Rate(RA-LL impedance and nasal cavity)Measurement range: 0 - 120 BPM(adult)Accuracy: ± 1 BPM or 5 %Resolution: 1 BPM
Environment Operation StorageTemperature 0.5 - 40ºC -20 - 50ºCRelative humidity ≤ 80%
Pulse RateSPO2 measurement range: 0 - 100 %Resolution: 1 %Pulse measurement range: 30- 254BPMAccuracy: ± 2 %Resolution: 1 BPM
NIBP (Non-invasive blood pressure)
Measurement type: Adult, pediatric, neonatal Measurement range: Systolic 4.0 - 37.0 kPa Diastolic 1.3 - 33.0 kPa Mean 2.6 - 35.0 kPaAccuracy: ± 0.4 kPa or 5 %Resolution: 0.1 kPaProtection: Over pressure
IBP(Invasive blood pressure) (with venous punch)
(Option)Measurement range: -1.3~40kPa (-10~300mmHg) Channel: 2 channelTransducer sensitivity: 5MV/V/mmHg Unit display: KPa or mmHg selectable
Power requirements Input: 98~260 V AC, 50/60HzConsumption: ≤ 80VA
Safety standard: IEC 60601-1
Quality System: ISO13485: 2003
Packaging & Shipping
Packaging |
Standard export corrugated paper board cartons or wooden box |
Pallet |
Plastic/ Wooden pallet |
Shipping |
By sea/ By air/ By courier (DHL, FEDEX, UPS, TNT) |
Our Advantage :
1: For all your inquires about us or our products , we will reply you in detail within 24 hours.
2: We own professional team have professional attitude to recommend products and services.
3:One year free warranty , after it is still providing after-sales service .
4: We offer OEM services , Can print your own logo on the products .
5:We have very experienced engineers , can help you better use our products .