Customization: | Available |
---|---|
Name: | Mechanical Arms Medical Movable Anesthesia Machine |
Flow Meter: | O2: 0.1~1.0L/Min 1.1~10L/Min |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Main body: High-strength engineering plastic rack, light,
beautiful and corrosion resistant
2. Scope of application:adult, child
3. Gas source:O2: 0.27~0.55MPa N2O: 0.27~0.55MPa
4. Flow meter:O2: 0.1~1.0L/min 1.1~10L/min
N20: 0.1~1.0L/min 1.1~10L/min
5. O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
6. Flow rate of rapid oxygen supply 25~75L/min
7. Low oxygen pressure alarm
There will be sound alarm when the oxygen pressure < 0.2MPa
8. Vaporizer
it has the function of automatic compensation based on pressure, temperature, and flow rate
The regulation range : evaporator concentration is 0~5 vol%. Among Halothane,Enflurane, Isoflurane and Sevoflurane,
one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
9. Respiratory circuit:working mode: all-close, semi-close, semi-open
releasing pressure: 0.5~7 kPa
10. Respiratory Bellows:bellows for adults, bellows for children
tidal volume range:0~1,500 ml
Ventilator:
1. Display mode:High-definition TFT color LCD screen display
2. Ventilation mode:IPPV, SIPPV, SIMV, PEEP, MANUAL,
SIGH, (IMV, VCV, PCV)
3. Ventilation parameters
Tidal volume:50~1500 ml (20~1500 ml)
Rate:1~99 bpm
SIMV rate:2~20 bpm
I:E:2:1~1:8 (4:1~1:8)
Inspiratory trigger pressure :-1.0~2.0Kpa
PEEP:0~2.0Kpa
Pressure Range:1.0~6.0Kpa
SIGH:1.5 times the inspiratory time (70-150 adjustable)
Inspiratory platform: 0~50%
4. Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate,I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance,
airway resistance,flow
-volume oop,pressure-volume loop)
5. Monitoring of oxygen concentration:21%~100%
6. Security Alarm System
Oxygen Concentration alarm : upper limit setting range:21%~100%
low limit setting range:10%~80%
Airway pressure alarm :upper limit setting range:0.3~6.0 kPa
low limit setting range:0.2~5.0 kPa
Per-minute ventilation volume alarm
upper limit setting range :3.0~30L/min
low limit setting range:1.0~10L/min
Sustained high-pressure alarm : will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm : it will give sound and light alarm if there
is no tidal volume input for 15 seconds
Power alarm
6. Power:AC 220V±10% 50Hz±1Hz
(UPS, Storage battery)
7. (Mechanical Arms)
8. (End-expiratory CO2 monitoring)Product name |
MY-E009 Mechanical Arms medical movable anesthesia machine |
Brand name | MAYA |
Packaging Details | Carton box for MY-E009 Mechanical Arms medical movable anesthesia machine |
Delivery Detail | |
Payment Terms | T/T, Western Union, Money Gram |
Port | Guangzhou |