My-E010 Medical Device Multifunctional Anesthesia Machine

Product Details
Customization: Available
Name: My-E010 Medical Device Multifunctional Anesthesia
Flow Meter: O2: 0.1~1.0L/Min, N20: 0.1~1.0L/Min
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 19 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • My-E010 Medical Device Multifunctional Anesthesia Machine
  • My-E010 Medical Device Multifunctional Anesthesia Machine
  • My-E010 Medical Device Multifunctional Anesthesia Machine
  • My-E010 Medical Device Multifunctional Anesthesia Machine
  • My-E010 Medical Device Multifunctional Anesthesia Machine
  • My-E010 Medical Device Multifunctional Anesthesia Machine
Find Similar Products

Basic Info.

Model NO.
MY-E010
Gas Source
O2: 0.27~0.55MPa N2o: 0.27~0.55MPa
Scope of Application
Adult, Child
Flow Rate of Rapid Oxygen Supply
25~75L/Min
Display Mode
High-Definition 5.7" LCD Screen Display
Ventilation Mode
Ippv, Sippv, Simv, Peep, Manual, Sigh
Tidal Volume
50~1500 Ml (20~1500 Ml)
Rate
2~99 Bpm
Simv Rate
2~20 Bpm
Transport Package
Wooden Box
Specification
CE, RoHS, SGS, GMP
Trademark
MAYA
Origin
Guangdong, China (Mainland)
Production Capacity
200set/Month

Product Description

MY-E010 medical device Multifunctional Anesthesia Machine:

1. Main body:High-strength engineering plastic rack, light,

beautiful and corrosion resistant

2. Scope of application          adult, child

3. Gas source                O2: 0.27~0.55MPa    N2O: 0.27~0.55MPa

4. Flow meter                 O2:  0.1~1.0L/min     1.1~10L/min

                                      N20: 0.1~1.0L/min     1.1~10L/min

5. O2, N2O linkage and N2O Stopper

  When using nitrous oxide, oxygen concentration>25%;

  When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.

6. Flow rate of rapid oxygen supply   25~75L/min

7. Low oxygen pressure alarm    There will be sound alarm when the oxygen

pressure < 0.2MPa

8. Vaporizer                  it has the function of automatic compensation based on pressure, temperature, 

and flow rate. The regulation range of evaporator concentration is 0~5 vol%.

Among Halothane,Enflurane,Isoflurane and Sevoflurane,two can be chosen for application as required 

by the customer. And vaporizers that are imported with original packaging are also available.

9. Respiratory circuit               working mode: all-close, semi-close, semi-open APL: 0.5~7 kPa

10. Respiratory Bellows          bellows for adults, bellows for children tidal volume range:0~1,500 ml

 

11. Display mode                        High-definition 5.7" LCD screen display

12. Ventilation mode                  IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH

13. Ventilation parameters        Tidal volume         50~1500 ml

Rate                   2~99 bpm

SIMV rate           2~20 bpm

Inspiratory trigger pressure      -1.0~2.0 kPa

PEEP                                          0~2.0 kPa

Pressure range                          1.0~6.0 kPa

SIGH                                          1.5 times the inspiratory time

14. Parameters for ventilation monitoring  tidal volume, ventilation volume, IPPV rate, SIMV rate, total 

respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure

15. Monitoring of oxygen concentration  (21%~100%)

16. Security Alarm System

Oxygen Concentration alarm    upper limit setting range   (50%~100%)

                                                 low limit setting range    (15%~50%)

Airway pressure alarm         upper limit setting range   1.0~6.0 kPa

                                            low limit setting range    0.4~2.0 kPa

Per-minute ventilation volume alarm      upper limit setting range   3.0~30L/min low limit setting range    

1.0~10L/min

Sustained high-pressure alarm       it will give alarm when stress have consistently been higher than 2.5 kPa

Suffocation alarm             it will give sound and light alarm if there is no tidal volume input for 15 seconds

Power alarm

17. Power                       AC 220V±10%     50Hz±1  (UPS, Storage battery)

18. (Mechanical Arms)

19. (End-expiratory CO2 monitoring)
My-E010 Medical Device Multifunctional Anesthesia Machine

 

 


Product name
MY-E010 medical device Multifunctional Anesthesia Machine
Brand name MAYA
Packaging Details Carton box for MY-E010 medical device Multifunctional Anesthesia Machine
Delivery Detail  
Payment Terms T/T, Western Union, Money Gram
Port Guangzhou


Our Advantage :
1: For all your inquires about us or our products , we will reply you in detail within 24 hours.
2: We own professional team have professional attitude to recommend products and services.
3:One year free warranty , after it is still providing after-sales service .
4: We offer OEM services , Can print your own logo on the products .
5:We have very experienced engineers , can help you better use our products .


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More