My-D011 200mA Diagnostic X-ray System

  • Audited Supplier
  • 15 yrs

Contact Supplier

Product Highlights

  • 200mA High Output: Max DC output current reaches 200mA for efficient diagnostic imaging.
  • Rotary Anode Tube: Features a rotary anode X-ray tube unit with tangential annular head.
  • Digital Timer Control: Adopts digital circuit timer with R10 priority coefficient for accuracy.
  • Adjustable Table: Radiographic table moves 640mm in length and 200mm in breadth.
  • OEM/ODM Support: Offers full, minor, and flexible customization from samples or designs.
  • 100% Quality Inspection: Finished products undergo 100% visual and function inspection.
  • Flexible Payment Terms: Supports LC, T/T, D/P, PayPal, Western Union, and small payments.
  • Fast Lead Time: Average lead time within 15 workdays for both peak and off seasons.

Product Images of My-D011 200mA Diagnostic X-ray System

My-D011 200mA Diagnostic X-ray System
My-D011 200mA Diagnostic X-ray System pictures & photos
My-D011 200mA Diagnostic X-ray System
My-D011 200mA Diagnostic X-ray System pictures & photos
My-D011 200mA Diagnostic X-ray System
My-D011 200mA Diagnostic X-ray System pictures & photos
My-D011 200mA Diagnostic X-ray System
My-D011 200mA Diagnostic X-ray System pictures & photos
My-D011 200mA Diagnostic X-ray System
My-D011 200mA Diagnostic X-ray System pictures & photos
My-D011 200mA Diagnostic X-ray System
My-D011 200mA Diagnostic X-ray System pictures & photos
My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System
    My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System
    My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System
    My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System
    My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System
    My-D011 200mA Diagnostic X-ray System
  • My-D011 200mA Diagnostic X-ray System
    My-D011 200mA Diagnostic X-ray System

Find Similar Products

Product Description

MY-D011 200mA Diagnostic X-ray System
My-D011 200mA Diagnostic X-ray System
Detailed Product Description
1, MA200A 200mA Medical X-ray model
2, Special in radiography
3, tube currency is 200mA

MA200A 200mA Medical X-ray System
USE
General radiography, Filter-ray-filter radiograph

Unit Configuration
Control, HT generator unit, Ht cable, X-ray tube unit, Radiographic table-X-ray source column, Collimator

MAIN CHARACTERISTICS
1, Single-table/single-tube

2, Rotary anode X-ray tube unit and tangential annular tube head

3, Single-phase full wave rectification high-voltage generator

4, Power voltage(v) radiograph kilovolt (KV). Step-less control electric mechanism

5, Filament stabilizer for X-ray tube unit and space charge compel mentor

6, Radiograph volume KV, MA and S. Grading and interlock protection

7, Adopt digital circuit timer. Grading according to R10 priority coefficient, (for more accurately controlling time)

8, HT primary, the zero controlled circuit of silicon-controlled rectifier of heavy power

9, Radiographic table can move in length an breadth

10, The radiographic table. Column and vibrating grid are in a whole without ceiling and floor rails bottom
ITEM CONTENTS INDEX
Demand  of  power  supply Capacity Two-phase  30KVA
Voltage, Frequency 380V/220V      ± 10%50HZ  ± 0.5Hz
    Intemal    resistance 0.752Ω (380V)    0.25Ω (220V)
power  supply Adjustable  range 380± 10%  at220V  being  adjustable  continuously
Radiograph Voltage 50-100KV       
        50-100KV    being    adjustable    continuously
current Small  focus: 50mA100mA, Big  focus: 50mA  100mA    200mA    300mA
time 0.04~6.35s  23grades  together  grading  a  according  to  R10  coefficient
High-voltage  generator Capacity 20KVA(instantaneous)
Max  DC  output  voltage 100KV
Max  DC  output  current 200mA
X-Ray  tube Model XD51.20-40/100
Focus Small  focus  1× 1mm    big  focus2× 2mm
Radiographic  table Length× width× height  of  bed  surface 2000mm× 665mm× 700mm
Moving  range  of  bed  surface 640mm  in  Length, 200mmin  breadth
Ray-filter  of  table Travel  in  length  ≥ 500mm
Grid  density  N=28
Convergence  distance  f. =100cm
Grid  ratio  r=8
Column  of  X-ray  tube  unit Moving  Longitudinally  along
Radiographic  table
1000mm  or  1800mm
Distance  to  friend  as  moving  up  and  down  (along  column) 650~1800mm
Rotary  around  the  center  of  cross  arm ± 180°
Rotary  around  the  shaft  line  of
X-ray  annular  tubes
-10° ~60° ~    +120°
Max  size  of  cassette 356mm× 432mm    (14″ × 17″ )

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR2311451". Items marked "verified" are certified.

Watch Video
Watch Video
Guangzhou Maya Medical Equipment Co., Ltd.
Guangzhou Maya Medical Equipment Co., Ltd.
Guangzhou Maya Medical Equipment Co., Ltd.
Guangzhou Maya Medical Equipment Co., Ltd.
Guangzhou Maya Medical Equipment Co., Ltd.
Guangzhou Maya Medical Equipment Co., Ltd.
Guangzhou Maya Medical Equipment Co., Ltd.
Guangzhou Maya Medical Equipment Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Room 102, First Floor, No. 2 Building, Bohou Industrial Park, No. 773 Xingnan Avenue, Nancun Town, Panyu District, Guangzhou, Guangdong, China
verified Plant Area
1200 square meters
verified Number of Employees
31
verified Registered Capital
1,010,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Guangzhou Port, Shenzhen Port
verified Supply Chain Partners
25

Our Production Capability & Technical Expertise

Main Products
Medical Equipment, Medical X-ray Machine, B Ultrasound Scanner, Hemodialysis Machine, Patient Monitor, Anesthesia Machine, Medical Disposable Material, Dental Equipment, Laboratory Equipment, Hospital Furniture
verified Production Lines
3
verified Production Machines
Cutting machine, Drilling Machine, milling machine, Super mute terminal machine, punching machine
verified QA/QC inspectors
3 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
2 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2011-12-05
verified Export Year
12 years
verified Main Markets
Africa
verified Repeat Buyers Choice
30%~50%
verified Number of Foreign Trading Staff
19
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

What is the maximum DC output current?
The maximum DC output current is 200mA.
What is the voltage range for the X-ray system?
The radiograph voltage is adjustable continuously from 50-100KV.
Can the radiographic table move?
Yes, the table can move 640mm in length and 200mm in breadth.
Is OEM or ODM service available?
Yes, we offer OEM, ODM, and various customization options.
What are the payment terms?
We accept LC, T/T, D/P, PayPal, Western Union, and small-amount payments.
What is the lead time for production?
The average lead time is within 15 workdays for both peak and off seasons.
What is the warranty or quality guarantee?
All finished products undergo 100% visual and function inspection.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs