• 100mA Medical X-ray Equipment
  • 100mA Medical X-ray Equipment
  • 100mA Medical X-ray Equipment
  • 100mA Medical X-ray Equipment
  • 100mA Medical X-ray Equipment
  • 100mA Medical X-ray Equipment

100mA Medical X-ray Equipment

Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Moving Latitudinal: 360mm
Voltage: 220V/380(Single Phase )
Frequency: 50Hz± 0.5Hz
Capacity: 10kVA
Customization:

Contact Supplier

Diamond Member Since 2012

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
MY-D006
Spot Film
100mA(Fixed)
Model
Xd4-2.9/100
Rotary Angle
+90 ° ~0~-5 °
Current
Small Focus 15mA, Big Foc
Time
(0.04-6.3s, 24grades Together)
Large Focus
30mA
Transport Package
Export Wooden Box
Specification
CE
Trademark
MAYA
Origin
China
Production Capacity
500PCS/Year

Product Description

Product Description

 

MY-D006 100mA Medical X-ray Equipment
1, 100mA Medical X-ray Equipment, X-ray equipment for hospitals 100mA Medical X-ray Equipment

USE
Fluoroscopy, Digestive track spot film radiography, General radiography, Filter-ray device radiography
Unit Configuration
Control, HT generator unit, Ht cable, X-ray tube unit, Diagnostic table, Column

MAIN CHARACTERIDTICS
1, Single table and single tube
2, Design according to the electric mechanism of middle-size machine, The function is reasonable
3, The high-tension system is of split structure. Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit, with large output power and reliable and stable operation
4, Supply voltage (V), roentgenoscopy, radiography (kv) and stepless adjust able

5, Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output
6, Equipped with the capacity limitation and portection circuit and KV mA S interlock limitation and protection
7, Adopt the digial circuit timer, grade according to R10 priority coefficient and can control time exactly,

8, Diagnostic table is of electric back rotation and is equipped with vibrating filter-ray device
9, The spot film device of luminescent serene can hold the film jacket of various sizes and can make the photography of full-film and two sectional films separateiy.
10, The column post hast has the bottom track only, which is easy while installation
ITEM CONTENTS INDEX
Upright  post(column) Moving  longitudinally(along  the  bottom  track) 1500mm
Moving  latitudinal 360mm
Moving  up  and  down from  focus  to  ground
Supply  power Voltage 220V/380(single  phase  )
Frequency 50Hz± 0.5Hz
Capacity 10KVA
Intemal  resistance 380v: 2Ω , 220V: 0.6Ω
Max  DC  output  voltage 50-90KV
Max  DC  output  current 100mA
Fluoroscopy Voltage 50-90KV
current ≤ 5mA
Radiograph Voltage 50-90KV
current Small  focus  15mA  ,   big  focus30mA  60mA  100mA
spot  film 100mA(fixed)
time (0.04-6.3s, 24grades  together)
High-voltage  generator Capacity 7KVA
X-Ray  tube Model XD4-2.9/100
Focus Small  focus  1.8mm    big  focus4.3mm
Diagnostic  table rotary  angle +90° ~0~-5°
specification  of  spot  film  (stomach  and  intestines  photography) 128× 179mm(5" × 7" )
205× 254mm(8" × 10" )
254× 305mm(10" × 12" )
MAX  VOLUME  OF  RADIOGRAPH
Focus  of  X-Ray  tube Radiograph  mA Max  Radiograph  KV Max  exposure  time  allow
Small  focus 15mA 90KV 6.3S
Large  focus 30mA 90KV 6.3S
60mA 90KV 6.3S
100mA 85KV 2.5S
             
Note:   We  will  not  make  another  notice  if  the  contour  of  product  and  technical  parameters  will  be  changed
 
 
 
ITEM CONTENTS INDEX
Upright  post(column) Moving  longitudinally(along  the  bottom  track) 1500mm
Moving  latitudinal 360mm
Moving  up  and  down from  focus  to  ground
Supply  power Voltage 220V/380(single  phase  )
Frequency 50Hz ± 0.5Hz
Capacity 10KVA
Intemal  resistance 380v: 2 Ω , 220V: 0.6 Ω
Max  DC  output  voltage 50-90KV
Max  DC  output  current 100mA
Fluoroscopy Voltage 50-90KV
current ≤ 5mA
Radiograph Voltage 50-90KV
current Small  focus  15mA  ,   big  focus30mA  60mA  100mA
spot  film 100mA(fixed)
time (0.04-6.3s, 24grades  together)
High-voltage  generator Capacity 7KVA
X-Ray  tube Model XD4-2.9/100
Focus Small  focus  1.8mm    big  focus4.3mm
Diagnostic  table rotary  angle +90 ° ~0~-5 °
specification  of  spot  film  (stomach  and  intestines  photography) 128 × 179mm(5 " × 7 " )
205 × 254mm(8 " × 10 " )
254 × 305mm(10 " × 12 " )
MAX  VOLUME  OF  RADIOGRAPH
Focus  of  X-Ray  tube Radiograph  mA Max  Radiograph  KV Max  exposure  time  allow
Small  focus 15mA 90KV 6.3S
Large  focus 30mA 90KV 6.3S
60mA 90KV 6.3S
100mA 85KV 2.5S
             

Send your message to this supplier

*From:
*To:
avatar Ms. Nancy
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

Diamond Member Since 2012

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
31
Type of Ownership
Limited Company