Product Description
My-C007 Portable Patient Monitor with Low Price
Description:
Standard configuration: ECG, HR, PR, SpO2, OxyCRG diagram, ST analysis, Arrhythmia analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation and lead-acid battery, remote control.
Optional configuration:
Wireless networking function to patient monitor;
Inside placed thermal-sensitive built-in printer;
IBP function (Include 1 pressure sensor and 1 adaptable cable);
ETCO2 function module(Respironics-main stream/side stream)-plug&play;
Cardiac Output
Wall Mount for patient monitor;
Trolly for patient monitor;
12 volts Power supply for ambulance
Accessories for Standard configuration:
1 remote controller |
1 set of ECG cable |
10 PCS of ECG electrode |
1 set of NIBP extend cable |
1 set of NIBP adult or pediatric or neonate cuff |
1 set of RESP nasal cavity pipe |
1 set of TEMP surface probe |
1 set of TEMP cavity probe |
1 set of integrated adult or pediatric or neonate SpO2 sensor |
1 set of power supply cable |
E CGInput: 5 wires ECG cable Lead section: I, II, III/ AVR, aVL, aVF/ V Gain(mm/mV): 1/4, 1/2, 1, 2, 4Sweep speed(mm/sec): 6.25, 12.5, 25, 50 Heart rate range: 15-300 BPMHeart rate accuracy: ± 1 %ST segment deviation analysis
NIBP (Non-invasive blood pressure) ()
Measurement type: Adult, pediatric, neonatal Measurement range: Systolic 4.0 - 37.0 kPa Diastolic 1.3 - 33.0 kPa Mean 2.6 - 35.0 kPaAccuracy: ± 0.4 kPa or 5 %Resolution: 0.1 kPaProtection: Over pressure
Tourniquet function
Temperature (surface and rectal)Measurement range: 25.0 - 45.0 CAccuracy: ± 0.1 CResolution: 0.1 Cresponse time: ≤ 3 min.
Respiration Rate(RA-LL, RA-LA, LL-LA selectable impedance and nasal cavity) Measurement range: 0 - 120 BPMAccuracy: ± 1 BPM or 5 %Resolution: 1 BPM
Pulse RateSPO2 measurement range: 0 - 100 %Resolution: 1 %Pulse measurement range: 30- 250BPMAccuracy: ± 2 %Resolution: 1 BPM
IBP(Invasive blood pressure) (Option)Measurement range: -1.3~40kPa (-10~300mmHg) Channel: 4 channelTransducer sensitivity: 5MV/V/mmHg Unit display: KPa or mmHg selectable
ETCO2 (main/side stream type) (Option) - Plug&PlayMeasurement range: 0- 150 mmHg 0 -19.7% 0 - 20kpa
(Barometric pressure supplied by Host)Accuracy: 0- 40 mmHg ± 2mmHg
41-70 mmHg ± 5% of reading
71-100mmHg± 8% of reading
101-150mmHg± 10% of reading
Above 80 breath per minute± 12% of reading
*NOTE: Gas temperature at 25 CSample rate: 50ml/minResponse time: < 3 seconds - includes transport time and rise time
Cardiac Output (Option)
Meathod: Thermodilution
Measurement range: CO: 0.1-20.0 L/min
TB: 23-43 C TI: 0 - 27 C Resolution: CO: 0.1 L/min
TI: 0.1C TB: 0.1C
Accuracy: CO: ± 0.2 L/min or ± 5%
TB: ± 0.2 C TI: ± 0.2CParameter output:
Cardiac output Hemodynamics calculation
Power requirements Input: 100~240 V AC, 50/60Hz Consumption: ≤ 80VA Environment Operation Storage Temperature 0.5 - 40 C -20 - 50 C Relative humidity ≤ 80%
Safety standard: IEC 60601-1
Quality System: ISO13485: 2003