Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Model | MY-D047 |
Product Name | UC-Arm Digital X-ray Radiography System (CCD-DR) |
Specifications |
|
Generator |
|
CPI High Frequency High Voltage Generator | Made in Canada |
Power | 50KW |
Frequency | 100KHZ |
Photography (mAS) | 0.1-630mAs |
Photography (KV) | 40-150KV |
Tube |
|
Toshiba Tube (Standard configuration) | Made in Japan |
Focus | 0. 6/1.5MM |
Photography (KV) | 40-125KV |
Heat Capacity | 200KHU |
VARIAN RAD-14 Tube (Optional) | Made in U.S.A |
Focus | 0. 6/1.2MM |
Photography (KV) | 40-150KV |
Heat Capacity | 300KHU |
CCD Detector |
|
Image Size | 17 x 17 inch |
Imaging Time | ≤ 10 S |
Transmission Time | ≤ 2 S |
A/D Conversion | 16 bit/65535 degree |
Image pixels | ≥ 9 Megapixel |
Limiting resolution | ≥3.4 LP/MM |
Kodak CCD Chip | Made in U.S.A |
Blinding Screen | CsI |
Refrigeration | Semi-conductor |
Service life | Theoretically there is no life limit |
AEC (Automatic Exposure Control System) |
|
Number of measuring fields | 3 |
Grid |
|
JPI Grid | Made in Korea |
Type | Stationary |
Size | 18″×18″ |
Grid ratio | 8:1 |
Density | 70L/cm |
Focus | 130cm |
Collimator |
|
DS Collimator | Made in Korea |
Operation method | Manual |
Vision | square |
Indicator light time limit | 30 seconds±20% |
Radiography Stand |
|
Type | UC-Arm Radiography Stand |
Cross arm movement range | (55-165)cm±3cm,continuously adjustable |
Cross arm rotates around rotation center (under condition of safe rotation height) |
(-30 -120)°±2° |
Focus screen distance | (100-180)cm±5cm,continuously adjustable |
Table |
|
Length | 200cm(±3 cm) |
Height | 70cm(±3 cm) |
Width | 65cm(±3 cm) |
Locking mode | mechanical locking |
Aluminium equivalent | < 1.7mmAl |
Dell Image Capture & Processing Workstation |
|
Lowest standard configuration |
Core Duo 2.5GHz, 2GB RAM, Hard disk 320GB, 19 inch LED (1 set), 100M network interface, DICOM3.0 interface. |
Automatic Exposure Image- Capture Software System |
|
One button hand brake | Doctors only need to press hand brake down and then all the exposure terms are automatically finished. |
Image Capture and Processing Software |
|
Multifunctional: Manual /automatic window width / window level, preset window width / window level, positive and negative image turning, image turning, image rotation, image amplification and roaming, labeling and measuring, splitting, automatic electron cutting, part amplification, recovering original image. |
|
Image Processing Technique: a) Dynamic scope optimization technique b) High frequency image enhancement technique c) Noise suppression technique automatically d) Edge enhancement technique |
|