| Customization: | Available |
|---|---|
| Classification: | Imaging Diagnostic Equipment |
| Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Product Model | |
| Product Name | UC-Arm Digital X-ray Radiography System (CCD-DR) |
Specifications |
|
Generator |
|
| CPI High Frequency High Voltage Generator | Made in Canada |
| Power | 50KW |
| Frequency | 100KHZ |
| Photography (mAS) | 0.1-630mAs |
| Photography (KV) | 40-150KV |
Tube |
|
| Toshiba Tube (Standard configuration) | Made in Japan |
| Focus | 0. 6/1.5MM |
| Photography (KV) | 40-125KV |
| Heat Capacity | 200KHU |
| VARIAN RAD-14 Tube (Optional) | Made in U.S.A |
| Focus | 0. 6/1.2MM |
| Photography (KV) | 40-150KV |
| Heat Capacity | 300KHU |
CCD Detector |
|
| Image Size | 17 x 17 inch |
| Imaging Time | ≤ 10 S |
| Transmission Time | ≤ 2 S |
| A/D Conversion | 16 bit/65535 degree |
| Image pixels | ≥ 9 Megapixel |
| Limiting resolution | ≥3.4 LP/MM |
| Kodak CCD Chip | Made in U.S.A |
| Blinding Screen | CsI |
| Refrigeration | Semi-conductor |
| Service life | Theoretically there is no life limit |
AEC (Automatic Exposure Control System)(optional) |
|
| Number of measuring fields | 3 |
Grid |
|
| JPI Grid | Made in Korea |
| Type | Stationary |
| Size | 18″×18″ |
| Grid ratio | 8:1 |
| Density | 70L/cm |
| Focus | 130cm |
Collimator |
|
| DS Collimator | Made in Korea |
| Operation method | Manual |
| Vision | square |
| Indicator light time limit | 30 seconds±20% |
Radiography Stand |
|
| Type | UC-Arm Radiography Stand |
| Cross arm movement range | (55-165)cm±3cm,continuously adjustable |
| Cross arm rotates around rotation center (under condition of safe rotation height) |
(-30 -120)°±2° |
| Focus screen distance | (100-180)cm±5cm,continuously adjustable |
Table |
|
| Length | 200cm(±3 cm) |
| Height | 70cm(±3 cm) |
| Width | 65cm(±3 cm) |
| Locking mode | mechanical locking |
| Aluminium equivalent | < 1.7mmAl |
Dell Image Capture & Processing Workstation |
|
| Lowest standard configuration |
Core Duo 2.5GHz, 2GB RAM, Hard disk 320GB, 19 inch LED (1 set), 100M network interface, DICOM3.0 interface. |
Automatic Exposure Image- Capture Software System |
|
| One button hand brake | Doctors only need to press hand brake down and then all the exposure terms are automatically finished. |
Image Capture and Processing Software |
|
| Multifunctional: Manual /automatic window width / window level, preset window width / window level, positive and negative image turning, image turning, image rotation, image amplification and roaming, labeling and measuring, splitting, automatic electron cutting, part amplification, recovering original image. |
|
| Image Processing Technique: a) Dynamic scope optimization technique b) High frequency image enhancement technique c) Noise suppression technique automatically d) Edge enhancement technique |
|
Image Printing Function |
|
| Manually selecting the target image for printing; Different printing devices, film format and printing pages available; DICOME3.0: @Print SCU; @Worklist SCU; @Storage SCU; @QR SCU; @MPPS SCU. |
|