Ma-8000A 7 Inch Portable Patient Monitor

Type: Patient Monitor
Certification: CE
Display: 7 Inch
Bandwidth: 0.1~2.5Hz
Adult Mode: 300 Mmhg
Children Mode: 240 Mmhg
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 19 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
MA-8000A
Neonatal Baby Mode
150 Mmhg
Color
White
Transport Package
Carton
Specification
CE
Trademark
maya
Origin
Guangdong
Production Capacity
500 Set Per Month

Product Description

Product Description

 

MA-8000A 7 inch portable patient monitor
Ma-8000A 7 Inch Portable Patient Monitor

Features of the 7 inch patient monitor:
4 Standard parameters: ECG, NIBP, SpO2, RESP. These four parameters are flexible. You
Can choose any parameters what you need.
7 inch high resolution color TFT LCD display.
Real time S-T segment analysis, pace-maker detection.
Indication of Incorrect manipulation and malfunction analysis.
Patient info input management function
Multi-lead ECG waveforms display in phase.
Large volume of tabular and graphic trends information storage and easy to recall.
Capture dynamic waveforms.
Efficient resistance to interference of defibrillator and HF knife.
UP to 4 hours working capacity of built-in rechargeable battery.
Unique accessory management cabinet.
Networking capacity.
Rechargeable Lithium battery
Suitable for adult, pediatrics and neonate patients.

RESP
Measuring Method
RA-LL impedance
RESP Impedance Measuring Range 0.3~3Ω
Base Impedance Range 200~4000Ω
Bandwidth 0.1~2.5Hz
RESP Rate
Range
Adult 0~120BrPM
Children and neonatal baby 0~150 BrPM
Resolution 1 BrPM
Precision 2 BrPM
Asphyxia Alarm 10~40 seconds

NIBP
Measuring Method Pulse wave oscillometry
Work Mode Manual/Automatic/STAT
Measuring Interval of Automatic Measuring Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minute(s)
Measuring Time of STAT Mode 5 minutes
PR range 40 240 bpm
Measuring Range and Precision

Range
Adult Systolic blood pressure 40~270mmHg
Diastolic blood pressure 10~215mmHg
Mean blood pressure 20~235mmHg
Children Systolic blood pressure 40~200mmHg
Diastolic blood pressure 10~150mmHg
Mean blood pressure 20~165mmHg
Neonatal baby Systolic blood pressure 40~135mmHg
Diastolic blood pressure 10~100mmHg
Mean blood pressure 20~110mmHg
Static pressure range 0~300mmHg
Static pressure precision 3mmHg
Pressure precision: Max. Average error: 5mmHg; Max.
Standard deviation: 8mmHg
Overvoltage protection
Adult mode 300 mmHg
Children mode 240 mmHg
Neonatal baby mode 150 mmHg
SpO2
Range 0~100%
Resolution 1%
Precision 70~100%: 2 DIGIT 0%~69%: No definition given
PR
Range 20~300bpm
Resolution 1bpm
Precision 3bpm

ECG
Lead configuration
Standard 3-lead or 5-lead
3-lead RA, LA, LL, Lead method: I, II, III
5-lead RA, LA, LL, RL, V, Lead method: I, II, III, AVR, aVL, aVF, V
Increase
250, 500, 1000, 2000
HR
Range
Adult 15 ~ 300bpm (beat/minute)
Neonatal baby/children 15 ~ 350 bpm(beat/minute)
Precision ± 1% or ± 1bpm, the larger prevails
Resolution 1 bpm(beat/minute)
Sensitivity > 200 UV (Peak-to-peak value)
Input Impedance > 5 (megohm)
Bandwidth
Diagnostic mode 0.05~130Hz
Monitoring Mode 0.5~40Hz
Operation mode 1~20Hz
Common Mode rejection Ratio
Diagnostic mode > 90 dB
Monitoring Mode > 100 dB
Operation mode > 100 dB
Pole Polarization Vvoltage Range 300Mv
Pacing Pulse Test
Test pacing pulse in accordance with the following conditions:
Amplitude: ± 2 mV ~ ± 700mV
Width: 0.1ms ~ 2ms
Risetime: 10us~100µ S
Pacing pulse inhibition
When pacing analysis switch is on, pacing pulse in accordance with the following
Conditions are restrained, but affection against HR calculation.
Amplitude: ± 2 mV ~ ± 700mV
Width: 0.1ms ~ 2ms
Risetime: 10us ~ 100µ S
Baseline Recovering Time
After defibrillation< 3 seconds
Signal Range 8 mV (Peak-to-peak value)

Calibrating Signal
1mV(Peak-to-peak value), precision 5%
ST Segment Measuring Volume
Measuring range: -2.0mV ~ +2.0mV
Measuring precision: Ranging -0.8 mV~+0.8mV, measuring error is ± 0.02mV or ± 10%, .
The larger prevails.
No definition for other ranges.