• My-A029 Color 3D 4D Full Digital Trolley Color Doppler Ultrasound Scanner
  • My-A029 Color 3D 4D Full Digital Trolley Color Doppler Ultrasound Scanner

My-A029 Color 3D 4D Full Digital Trolley Color Doppler Ultrasound Scanner

Classification: Imaging Diagnostic Equipment
Type: Ultrasound Scanner
Certification: CE, EEC, MSDS, ISO13485
Group: Middle-aged and Old
Model: My-A029 Color Doppler Ultrasound Scanner
Keywords: Doppler Ultrasound Scanner
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 19 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
MY-A029
Scan Mode
B, 2b, 4b, B/M, M, Cfm, Pw, Chroma B& M&Pw
Screen Size
19" High Resolution and Contrast LCD Monitor
Body Marker
Following Different Probe
Transport Package
Carton
Specification
standard
Trademark
MAYA
Origin
China
Production Capacity
500 Units/ Month

Product Description

Product Description

 

MY-A029 Color Doppler Ultrasound Scanner
My-A029 Color 3D 4D Full Digital Trolley Color Doppler Ultrasound Scanner

Just send your inquiry, that will be gone through within 24 hours.
Response Rate up to 99%, We will patiently answer your questions.

Features of MY-A029 Color Doppler Ultrasound Scanner
MY-A029 standard configuration includes : 23500
Main unit with 19" high resolution and contrast LCD Monitor  
1 PC 3.5 MHz convex probe D3C60L  
1 PC 7.5 MHz Linear probe D7L40L  
1 PC 6.0 MHz Trans-vaginal probe  
1 PC 3.0 MHz Phased array probe (Adult) D3P64L  
320GB hard disk, DVD-R/W and 6 USB ports  
B, 2B, 4B, B/M, M, CFM, PW, Power Doppler/Directional PD, Duplex, Trapezoidal, Chroma B& M&PW  
Measurement & calculation software packages (General, OB&GYN, Basic Cardiac )  
Easy View TM image archive system  
Optional Parts  
4D package(4.0 MHz 4D volume probe V4C40L +4D module + 4D software) 10000
4D module (Must order with main unit if need to be upgraded to 4D in future)
 
General Information 
Dimensions and Weight 
l  .Dimensions of main unit (approx.): 
     830mm  (Length)* 520 mm  (Width)*1458mm  (Height) 
l  .Net weight of main unit (approx):    125kg (no probe included) 
 
Electrical Power 
l  .Power supply voltage: AC 100V~240V 
l  .Power supply frequency: 50/60 Hz 
l  .Power consumption: 600 VA 
 
  User Interface 
Operation Panel 
    .Control panel 
l  .Alphanumeric keyboard 
l  .8 TGC Slides 
l  .Interactive backlit keys 
Display Screen 
l  .High resolution VGA color LCD 
     -  Diagonal dimension: 19 inch 
     -  Resolution: 1280X1024 
     -  Brightness adjustment 
l  .Integrated speaker 
     -   Volume adjustable
                           
       System Overview 
Applications 
l  .Abdomen 
l  .Cardiology 
l  .Gynecology 
l  .Obstetrics 
l  .Urology 
l  .mall Part 
l  .Pediatrics 
l  .Vascular 
l  .Musculoskeletal 
 
Transducer Types 
l  .3.5 MHz Wide Band Convex Probe (D3C60L) 
l  .7.5 MHz Wide Band Linear Probe (D7L40L) 
l  .6.0MHz Wide Band Transvaginal Probe (D6C12L) 
l  .3.0 MHz Wide Band Phased Array Sector Probe (D3P64L) 
l  .5.0MHz Wide Band Pediatric Probe (D5C20L) 
l  .4.0 MHz Wide Band 4D Probe (V4C40L) 
 
Image Modes 
l  .B Mode 
l  .B/B Mode 
l  .4B Mode 
l  .B/M Mode 
l  .CFM (Color Flow Mapping) Mode 
l  .B/BC Mode (B and CFM simultaneous comparison display) 
l  .PD (Power Doppler) Mode (CPA) 
l  .Directional PD (Power Doppler) Mode 
l  .PW (Pulse Wave) Mode 
l  .HPRF Mode 
l  .CW (Continuous Wave) Mode (option) 
l  .Color M Mode (option) 
l  .Steering M Mode (option) 
l  .Free-hand 3D (option) 
l  .Real-time 4D (upgradable) 
l  .Trapezoidal imaging (only for linear probe) 
l  .Panoramic imaging 
    .Real-time Duplex : B+CFM 
l  .Real-time Triplex : B+CFM+PW 
 
Display Mode 
l  .Simultaneous Capability 
     - B/PW 
     - B/CFM or PD (CPA), Directional PD 
     - B/M 
     - Real-time Triplex Mode 
     (B + CFM or PD (CPA)/PW) 
     - Dual B (B/B) 
     - B/BC in real time 
l  .Multi Image Split Screen 
     - Live and/or frozen 
     - B + B/CFM or PD (CPA) 
     - Independent Cine playback 
l  .Pan Zoom 
l  .Chroma 
     - Chroma B 
     - Chroma PW 
     - Chroma M 
l  .Trapezoid imaging (only for linear probe) 
l  .THI 
l  .Quad Screen Display 
 
Display Annotation 
l  .Institution/Hospital Name 
l  .Date: YY/MM/DD, MM/DD/YY, DD/MM/YY 
l  .Time: 24 hours 
l  .Operator Identification 
l  .Patient Name and Patient ID 
l  .System Status (real-time or frozen) 
l  .Image Preview 
l  .Gray/Color Bar 
l  .Cine Gauge 
l  .Scanning Direction 
l  .Focus Number 
l  .Measurement Summary Window 
l  .Measurement Results Window 
 
l  .Probe Type 
l  .Frequency 
l  .Application name 
l  .Imaging Parameters displayed on the screen 
     -B Mode 
         FPS 
         DYN 
         GSC 
         B Gain 
         SRA 
         Persist 
         Acoustic Power 
         Frequency 
         Depth 
         Zoom 
         THI 
         MI 
         TIS 
     -CFM Mode 
         PRF 
         Wall Filter 
         Color Gain 
         Color Map 
         Persist 
         CFM Acoustic Power 
         CFM Frequency 
         MI 
         TIS 
     -CPA Mode 
         PRF 
         Wall Filter 
         Color Gain 
         Color Map: Directional PD 
         Persist 
         PD (CPA) Acoustic Power 
         CFM Frequency 
         MI 
         TIS 
     -PW Mode 
         PRF 
         Wall filter 
         PW Gain 
         Frequency 
         PW Acoustic Power 
         DYN 
         GR 
         Sample Line Angle 
         MI 
         TIS 
         TIB 
     -CW Mode 
         PRF 
         Wall Filter 
         CW Gain 
         CW Frequency 
         CW Acoustic Power 
         DYN 
         GR 
         Sample Line Angle 
         MI 
         TIS 
         TIB 
     -M Mode 
         M Process: Peak, Ave 
         Sweep Speed 
         M Gain 
         M Acoustic Power 
         MI 
         TIS 
l  .Focus Markers 
l  .Body Marker: following different probe 
l  .System Messages Display 
l  .Trackball Functionality : CINE, ZOOM, Duplex, 3D, Position, Size 
l  .Biopsy Guide 
 
Standard Configuration 
l  .High resolution 19 Inch LCD display 
l  .4 active probe ports 
l  .320G integrated hard disk 
l  .DVD-RW driver 
l  .Patient Information Database 
l  .Image Archive on Hard Drive 
l  .Conversion of image/cine (Converting image/cine to PC format) 
l  .Real-time Triplex mode at any depth and PRF 
l  .USB ports: 2 on keyboard and another 4 on back panel 
l  .Frame rate (Up to 500 fps) 
l  .Automatic Optimization 
l  .Automatic Imaging Optimization (AIO) 
l  .Auto Doppler 
l  .Tissue Harmonic Imaging (THI) all on probes 
l  .Compound imaging 
l  .TSS (Tissue Speed of sound) 
l  .Up to 7000 frames CINE memory 
l  .B normal Calculation 
l  .M basic Calculation 
l  .Doppler basic Calculation 
l  .Vascular Calculation 
l  .Cardiac Calculation 
l  .OB Calculation 
l  .Fetal Trending 
l  .Gynecological Calculation 
l  .Urological Calculation 
l  .Renal Calculation 
l  .Auto Doppler Calculation 
l  .On-board Reporting 
l  .3.5 MHz Wide Band Convex Probe (D3C60L) 
 
Software Options 
l  .I-ImageTM software package 
l  .DICOM Connectivity 
l  .Free-hand 3D 
l  .Real-time 4D (upgradable) 
l  .Speckle Reduction Algorithm (SRA) 
l  .Multiple Compound Imaging (MCI) 
l  .Extended Cardiac package: CW, Color M, ECG, Steering M, TDI 
l  .VET 
 
Hardware Option 
l  .7.5 MHz Wide Band Linear Probe (D7L40L) 
l  .6.0MHz Wide Band Transvaginal Probe (D6C12L) 
l  .3.0 MHz Wide Band Phased Array Sector Probe (D3P64L) 
l  .5.0MHz Wide Band Pediatric Probe (D5C20L) 
l  .4.0 MHz Wide Band 4D Probe (V4C40L) 
l  .Biopsy guide 
l  .Footswitch 
    .Video printer: Sony UP897MD 
l  .PC printer 
                                    
   Scanning  Parameters 
B Mode 
l  .GAIN: 1~255 
l  .FOCAL NUMBER:1~9 (Depend on the probe types) 
l  .FOCAL SPAN: multiple selection(Depend on the probe types) 
l  .ECG GAIN: 1~6 
l  .ECG POSITION: 0~8 
l  .ECG INVERT: On/Off 
l  .TSS: -140-160(31 steps,10/step, the default value is 0) 
l  .DYN: 1~14 (Depend on the probe types) 
l  .GSC: 1~8 
l  .PERSIST: 0~60 (7 steps) 
l  .CHROMA: 1~13 
l  .SEC. WIDTH 
l  .SEC. POS 
l  .LINE DENSITY: Low, Med, High 
l  .COMPOUND: On/Off 
l  .FREQUENCY: 2.0~13.0 MHz (depend on the probe types) 
l  .LT← RT: Left/Right invert 
l  .SPA: 0-15 
l  .I-Image: X, A, B, C, D 
l  .POWER%:       30~100 (8 steps, 10/step) 
l  .TRAPEZOID: On/Off (depend on the probe types) 
 
M Mode 
l  .GAIN: 1~255 
l  .FOCAL NUMBER:1 ~9 Depend on the probe types 
l  .FOCAL SPAN: Depend on the probe types 
l  .ECG GAIN: 1~6 
l  .ECG POSITION: 0~8 
l  .ECG INVERT:On~Off 
l  .DYN: 1~14 
l  .GSC: 1~8 
l  .PERSIST: 0~60(7 steps) 
l  .CHROMA: 1~13 
l  .SEC. WIDTH 
l  .SEC. POS 
l  .LINE DENSITY: Low, Med, High 
l  .FREQUENCY          2.0~13.0 MHz (depend on the probe types) 
l  .UP← DOWN: Up/Down invert 
l  .LT← RT: Left/Right invert 
l  .POWER%:        30~100 (8 steps, 10/step) 
l  .VIDEO INVERT: On/ Off 
l  .M PROCESS:Ave,Peak 
l  .DISPLAY FORMAT: V1/3, V1/2, V2/3, H1/2, H1/4,O1/4 
 
CFM Mode 
l  .GAIN: 1~255 
l  .WF: 25-700 
l  .ECG GAIN: 1~6 
l  .ECG POSITION: 0~8 
l . ECG INVERT 
l  .PERSIST: 0~80 (5 steps) 
l  .C MAP: 4 selections 
l  .POWER%:        30-100 (8 steps, 10/step) 
l  .BASELINE: -5~5 
l  .SEC. WIDTH 
l  .SEC. POS 
l  .B REJECT: 0~255 
l  .FREQUENCY:2.0-7.2MHz (depend on the probe types) 
l  .LT← RT: Left/Right invert 
l  .FLOW INVERT: On/Off 
l  .2D REFRESH: On/Off 
l  .Steer:-20°~ 20°((depend on the probe types) 
l  .LINE DENSITY: Low, High 
 
PD Mode (CPA) 
l  .WF: 25-700 
l  .PRESIST: 0~80 (5 steps) 
l  .C MAP/DIRECT. D: 1~4 
l  .POWER%:        30-100 (8 steps, 10/step) 
l  .SEC. WIDTH 
l  .SEC. POS 
l  .B REJECT: 0~255 
l  .FREQUENCY: Depend on the probe types 
l  .LT← RT: Left/Right invert 
l  .LINE DENSITY: Low, High 
l  .Steer:-20°~ 20°((depend on the probe types) 
l  .GAIN: 0-255 
 
PW Mode 
l  .STEER ANGLE: -20~20 
l  .ECG: On/Off 
l  .ECG GAIN: 1~6 
l  .ECG POSITION: 0~8 
l  .ECG INVERT: On/Off 
l  .FREQUENCY 
l  .SWEEP SPEED: 4 steps (2, 4, 6, 8) 
l  .BASELINE: -5~5 
l  .POWER%:       30~100 (8 steps, 10/step) 
l  .ANGLE CORRECTION: On/Off 
l  .DYN: 1~10 
l  .CHROMA: 1~5 
l  .VIDEO INVERT: On/Off 
l  .DISPLAY FORMAT: V1/3, V1/2, V2/3, H1/2, H1/4, O1/4 
l  .WF: 25~750  (depend on the probe types) 
l  .Volume:0~100 
 
CW Mode 
l .SWEEP SPEED: 3 steps (2, 4, 8) 
l. BASELINE: -5~5 
l .POWER%:        30~100 (8 steps, 10/step) 
l .DYN: 1~10 
l .CHROMA: 1~5 
l .VIDEO INVERT: On/Off 
l .DISPLAY FORMAT: V1/3, V1/2, V2/3, H1/2, H1/4, O1/4 
l .WF: 100~70
   
Imaging  Processing and  Presentation 
l .(Dual Phase) Digital Beam former 
l .1024 Digital Processing Channel (ensures high frame rate) 
l .Displayed Imaging Depth: 3 - 29.6 cm probe dependent 
l .Minimum Depth of Field: 1.6 cm (Zoom and probe dependent) 
l .Maximum Depth of Field: 29.6 cm (probe dependent) 
l .Transmission Focus 1 - 9 Focus Numbers Selectable     (probe and depth dependent) 
l .Multi-Frequency/Wideband Technology 
l .256 Shades of Gray 
l .Up to 160 dB System Dynamic Range 
l .Adjustable Field of View (FOV) 
l .Image Reverse: Right/Left, Up/Down 
l .CINE Memory/Image Memory 
         21958 Frames CINE Memory on probe D3C60L 
         8041 Frames CINE Memory on probe D7L40L 
         11498 Frames CINE Memory on probe D3P64L 
l .CINE Gauge and CINE Image Number Display 
l .CINE Review: 
         Frame-by-frame, Loop (manual or automatic playback) 
l .Measurements, Calculations and Annotations on CINE Playback 
l .Image Browser: Archived images from past patient exams appear as well as images 
     stored for the current exam 
         -   Previewing an Image 
         -   Analyzing Images 
l. Image Management 
         -   Delete Selected Image 
         -   Copy and Paste 
         -   Convert to PC format 
         -   Analyze 
         -   Measurement: Distance, Trace, ellipse 
         -   Output 
l .Hard Drive Image Storage: 320 GB 
l .Ethernet Network Connection 
l .DICOM Support (option) 
 
  Measurement   &   Calculation 
Basic Measurements & Calculations 
l .Basic 2D mode (B and Color) Measurements 
     -Distance 
     -Circumference/Area (Ellipse / Trace) 
     -Volume (Two-axis / Three-axis) 
     -Angle 
     -DOPPLER AREA 
l .Basic M mode measurement 
     -DISTANCE 
     -TIME 
     -SLOPE 
     -HR 
l .Doppler Mode Measurement 
-Basic Doppler Measurements 
     -Flow Velocity 
     - Acceleration 
     -Time 
     -HR 
l .Auto Measurements (Auto Point, Auto Trace) 
     -Vp (Velocity at peak) 
     -Ve (Velocity at end) 
     -PPG (Pressure gradient at peak) 
     -EPG (Pressure gradient at end) 
     -Vmean(Mean Velocity) 
     -MPG (Mean Pressure gradient) 
     -PI (Pulsatility index) 
     -RI (Resistive index) 
     -VTI 
     -EnvTi 
     -S/D 
     -HR 
l .Manual Trace Measurements 
     -Vp (Velocity at peak) 
     -Ve (Velocity at end) 
     -PPG (Pressure gradient at peak) 
     -EPG (Pressure gradient at end) 
     -Vmean(Mean Velocity) 
     -MPG (Mean Pressure gradient) 
     -PI (Pulsatility index) 
     -RI (Resistive index) 
     -VTI 
     -EnvTi 
     -S/D 
     -HR 
l. Flow Velocity Measurement 
     -FV (Flow Velocity) 
     -PG (Pressure Gradient) 
l .Acceleration Measurement 
     -Vdf (Velocity Deviation) 
     -VAC (Acceleration) 
     -Peak V 
     -Time 
     -AccV 
     -PHT 
Cardiac Measurements & Calculations 
l .B mode Measurements and Calculation (Left Ventricle) 
-Single Plane Method 
     -LVALd (Left Ventricle Long-axis Area at End-diastole) 
     -LVLd (Left Ventricle Long-axis Length at End-diastole) 
     -LVALs (Left Ventricle Long-axis Area at End-systole) 
     -LVLs (Left Ventricle Long-axis Length at End-systole) 
     -EDV(End-diastolic Left Ventricle Volume) 
     -ESV(End-systolic Left Ventricle Volume) 
     -SV(Stroke Volume) 
     -CO(Cardiac Output) 
     -EF  (Ejection Fraction) 
     -SI 
     -CI 
-Biplane Ellipse Method 
     -LVALd (Left Ventricle Long-axis Area at End-diastole) 
     -LVALs (Left Ventricle Long-axis Area at End-systole) 
     -LVAMd (Left Ventricle Short-axis Area at the Level of Mitral Valve at End-diastole) 
     -LVIDd (Left Ventricle Short-axis Internal Diameter at End-diastole) 
     -LVAMs (Left Ventricle Short-axis Area at the Level of Mitral Valve at End-systole) 
     -LVIDs (Left Ventricle Short-axis Internal Diameter at End-systole) 
     -EDV(End-diastolic Left Ventricle Volume) 
     -ESV(End-systolic Left Ventricle Volume) 
     -SV(Stroke Volume) 
     -CO(Cardiac Output) 
     -EF  (Ejection Fraction) 
     -SI 
     -CI 
     -Bullet Method 
     -LVAMd (Left Ventricle Short-axis Area at the Level of Mitral Valve at End-diastole) 
     -LVAMs (Left Ventricle Short-axis Area at the Level of Mitral Valve at End-systole) 
     -LVLd (Left Ventricle Long-axis Length at End-diastole) 
     -LVLs (Left Ventricle Long-axis Length at End-systole) 
     -EDV(End-diastolic Left Ventricle Volume) 
     -ESV(End-systolic Left Ventricle Volume) 
     -SV(Stroke Volume) 
     -CO(Cardiac Output) 
     -EF  (Ejection Fraction) 
     -SI 
    -CI 
-Simpson Method 
     -LVAMd (Left Ventricle Short-axis Area at the Level of Mitral Valve at End-diastole) 
     -LVAMs (Left Ventricle Short-axis Area at the Level of Mitral Valve at End-systole) 
     -LVAPDd   (Left   Ventricle   Short-axis   Area   at   the   Level   of   the   Papillary   Muscle   at 
End-diastole) 
     -LVAPDs   (Left   Ventricle   Short-axis   Area   at   the   Level   of   the   Papillary   Muscle   at 
End-systole) 
     -LVLd (Left Ventricle Long-axis Length at End-diastole) 
     -LVLs (Left Ventricle Long-axis Length at End-systole) 
     -EDV (End-diastolic Left Ventricle Volume) 
     -ESV (End-systolic Left Ventricle Volume) 
     -SV (Stroke Volume) 
     -CO (Cardiac Output) 
     -EF (Ejection Fraction) 
     -SI 
     -CI 
-Cube Method 
     -IVSTd (Inter-ventricle Septal Thickness at End-diastole) 
     -LVIDd (Left Ventricle Short-axis Internal Diameter at End-diastole) 
     -LVPWd (Left Ventricle Posterior Wall Thickness at End-diastole) 
     -IVSTs (Inter-ventricle Septal Thickness at End-systole) 
     -LVIDs (Left Ventricle Short-axis Internal Diameter at End-systole) 
     -LVPWs (Left Ventricle Posterior Wall Thickness at End-systole) 
     -EDV (End-diastolic Left Ventricle Volume) 
     -ESV (End-systolic Left Ventricle Volume) 
     -SV (Stroke Volume) 
     -CO (Cardiac Output) 
     -EF (Ejection Fraction) 
     -FS (Fractional Shortening) 
     -dT IVS 
     -dT PW 
-Teichholz / Gibson Method 
     -LVIDd (Left Ventricle Short-axis Internal Diameter at End-diastole) 
     -LVIDs (Left Ventricle Short-axis Internal Diameter at End-systole) 
     -EDV (End-diastolic Left Ventricle Volume) 
     -ESV (End-systolic Left Ventricle Volume) 
     -SV (Stroke Volume) 
     -CO (Cardiac Output) 
     -EF (Ejection Fraction) 
     -FS (Fractional Shortening) 
     -SI 
     -CI 
-Biplanedisk 
     -LVAd 
     -LVLd 
     -LVAs 
     -LVLs 
     -EDV 
     -ESV 
     -SV 
     -CO 
     -EF 
     -SI 
     -CI 
l .M mode Measurements & calculations 
-Mitral Valve 
     -EFSLP (Mitral Valve Closing Speed) 
     -EPSS (Distance between point E and the Inter-ventricle Septum) 
     -CEAMP (Amplitude of the E Wave) 
     -CAAMP (Amplitude of the A Wave) 
     -DEAMP (Amplitude of the DE Wave) 
     -DESLP (Mitral Valve Opening Speed) 
     -E Duration 
     -A Duration 
     -IRT 
     -E-E' 
-Aortic Valve 
     -AOD (Diameter of the Aorta) 
     -LAD (Diameter of the Left Atrium) 
     -AVD (Diameter of the Aortic Valve) 
     -ET (Ejection Time) 
     -RVOTD (Diameter of the Right Ventricle Outflow Tract) 
     -AA 
-Left Ventricular 
   -Cube Method 
     -IVSd (Inter-ventricle Septal Thickness at End-diastole) 
     -LVIDd (Left Ventricle Short-axis Internal Diameter at End-diastole) 
     -LVPWd (Left Ventricle Posterior Wall Thickness at End-diastole) 
     -IVSs (Inter-ventricle Septal Thickness at End-systole) 
     -LVIDs (Left Ventricle Short-axis Internal Diameter at End-systole) 
     -LVPWs (Left Ventricle Posterior Wall Thickness at End-systole) 
     -EDV (End-diastolic Left Ventricle Volume) 
     -ESV (End-systolic Left Ventricle Volume) 
     -SV (Stroke Volume) 
     -CO (Cardiac Output) 
     -EF (Ejection Fraction) 
     -FS (Fractional Shortening) 
     -dT 
     -IVS 
     -dT PW 
     -MVCF 
-Teichholz / Gibson Method 
     -LVIDd (Left Ventricle Short-axis Internal Diameter at End-diastole) 
     -LVIDs (Left Ventricle Short-axis Internal Diameter at End-systole) 
     -EDV (End-diastolic Left Ventricle Volume) 
     -ESV (End-systolic Left Ventricle Volume) 
     -SV (Stroke Volume) 
     -CO (Cardiac Output) 
     -EF (Ejection Fraction) 
     -FS (Fractional Shortening) 
l .Doppler Measurements & Calculations 
-Mitral Valve 
     -E-wave V (E-wave Flow Velocity) 
     -A-wave V (A-wave Flow Velocity) 
     -PHT (Pressure Half Time) 
     -E Duration (E-wave Duration) 
     -A Duration (A-wave Duration) 
     -General date 
      Vp (Velocity at peak) 
      Ve (Velocity at end) 
      PPG(Pressure gradient at peak) 
      EPG(Pressure gradient at end)
      Vmean(Mean Velocity) 
      MPG(Mean Pressure gradient) 
      PI(Pulsatility index) 
      RI(Resistive index) 
      VTI 
      EnvTi 
      S/D 
      HR 
-Aortic Valve 
     -LVOT V/PG 
     -AOV V/PG 
     -LVOT/AOV General 
-     Vp (Velocity at peak) 
      Ve (Velocity at end) 
      PPG(Pressure gradient at peak) 
      EPG(Pressure gradient at end) 
      Vmean(Mean Velocity) 
      MPG(Mean Pressure gradient) 
      PI(Pulsatility index) 
      RI(Resistive index) 
      VTI 
      EnvTi 
      S/D 
      HR 
-TRI Valve 
     -TV General 
      Vp (Velocity at peak) 
      Ve (Velocity at end) 
      PPG(Pressure gradient at peak) 
      EPG(Pressure gradient at end) 
      Vmean(Mean Velocity) 
      MPG(Mean Pressure gradient) 
      PI(Pulsatility index) 
      RI(Resistive index) 
      VTI 
      EnvTi 
      S/D 
      HR 
     -TV V/PG 
-Pulmonary Valve 
     -PV General 
      Vp (Velocity at peak) 
      Ve (Velocity at end) 
      PPG(Pressure gradient at peak) 
      EPG(Pressure gradient at end) 
      Vmean(Mean Velocity) 
      MPG(Mean Pressure gradient) 
      PI(Pulsatility index) 
      RI(Resistive index) 
      VTI 
      EnvTi 
      S/D 
      HR 
     -RV ET (Ejection Time) 
     -RV AcT (Acceleration Time) 
     -RV PEP (Pre-ejection Period) 
-TEI index 
     -IRT(isovolumetric relaxation time) 
     -ICT(isovolumetric contraction time) 
     -ET(Ejection time) 
l. Cardiac worksheet 
     -Patient basic information 
     -Measurement value information 
     -Calculation information 
      EDV 
      ESV 
      SV 
      CO 
      EF 
      SI 
      CI 
      LA/AO 
      TEI index 
      FS 
      MVCF 
      IVS 
      PW 
      dT IVS 
      dT PW 
 
OB/GYN Measurements & Calculation 
l .OB (2D)-mode Measurements 
     -GS (Gestational Sac Diameter) 
     -CRL (Crown Rump Length) 
     -BPD (Biparietal Diameter) 
     -HC (Head Circumference) 
     -AC (Abdominal Circumference) 
     -FL (Femur Length) 
     -CER (Cerebellum) 
     -OFD (Occipitofrontal Diameter) 
     -Fibula (Fibula Length) 
     -Foot (Foot Length) 
     -AA (Abdominal Area) 
     -APAD (Anteroposterior Abdominal Diameter) 
     -HA (Head Area) 
     -Humerus (Humerus Length) 
     -Kidney (Kidney Length) 
     -APTD (Anteroposterior Trunk Diameter) 
     -OOD (outer orbital diameter) 
     -Radius (Radius Length) 
     -TAD (Transverse Abdominal Diameter) 
     -TC (Thoracic Circumference) 
     -THD (Thoracic Diameter) 
     -Tibia (Tibia Length) 
     -TTD (Transverse Trunk Diameter) 
     -Ulna (Ulna Length) 
     -Umb VD (Umbilical Vein Diameter) 
     -NT 
     -LV 
     -UT L (Uterus Length) 
     -UT H (Uterus Height) 
     -UT W (Uterus Width) 
     -CX 
     -EN-T 
     -Rt OVL (Right Ovary Length) 
     -Rt OVH (Right Ovary Height) 
     -Rt OVW (Right Ovary Width) 
     -Lt L (Left Ovary Length) 
     -Lt H (Left Ovary Height) 
     -Lt W (Left Ovary Width) 
     -HIP 
     -AFI (D1 D2 D3 D4) 
     -Follide 
l .OB (Doppler)-mode Measurements 
     -Umb A (Umbilical Artery) 
     -MCA (Middle Cerebral Artery) 
     -Rt Uterin A (Right Uterine Artery) 
     -Lt Uterin A (Left Uterine Artery)  
     -Fetal AO (Fetal Aorta) 
l OB/GYN Calculation 
     -MA (Menstrual Age) 
     -EFA (Estimated Fetal Age) 
     -EDD (Estimated Date of Delivery) 
     -EFW (Estimated Fetal Weight) 
     -Hip Angle 
     -AFI (Amniotic Fluid Index) 
     -Fetal HR 
     -Amniotic Fluid Index 
l .OB/GYN worksheet 
     -patient information 
     -Measurement values information 
     -Calculation information 
      MA 
      EFA 
      EDD 
      EFW 
      Hip Angle 
      AFI 
      CI 
     -Fetal growth curve 
      Normal growth curve, positive and negative standard deviations and ultrasound age 
of the fetus 
      One measurement per graph 
     -Profile 
      Fetal Brain 
      Fetal Thorax 
      Fetal Heart 
      Fetal Abdomen 
      Fetal Spine 
      Fetal Limb 
      Fetal Descript 
      Biophysical Profile 
     -Twinborn comparison 
 
Vascular Measurements and Calculation 
l .Vascular(2D and CFM) mode Measurement and Calculation 
     Origin Diam 
     Reduce Diam 
     Original Area 
     Reduced Area 
     % Diameter reduction 
     %Area reduction 
     -ICA (internal carotid artery) 
     -ECA (external carotid artery) 
     -CCA (Common Carotid artery) 
     -INT IL (Internal iliac) 
     -EXT IL  (External iliac) 
     -ILI AC  (common iliac) 
     -CFA  (Common femoral artery) 
     -PROFUN  (Profunda) 
     -LTCIR  (Lateral circumflex) 
     -SFA  (Superficial femoral artery) 
     -POP  (Popliteal artery) 
     -ATA   (Anterior tibial artery ) 
     -PERON  (Peroneal artery) 
     -PTA  (Posterior tibial artery) 
     -DRPED  (Dorsalis pedis) 
     -IMT 
l .Vascular (Doppler)Mode Measurement and Calculation 
     Vp (Velocity at peak) 
     Ve (Velocity at end) 
     PPG (Pressure gradient at peak) 
     EPG (Pressure gradient at end) 
     VM (Mean Velocity) 
     MPG(Mean Pressure gradient) 
     VTI 
     PI(Pulsatility index) 
     RI(Resistive index) 
     S/D 
     HR 
     FV (Flow volume) 
     -ICA (internal carotid artery) 
     -ECA (external carotid artery) 
     -CCA (Common Carotid artery) 
     -INT IL (Internal iliac) 
     -EXT IL  (External iliac) 
     -ILI AC  (common iliac) 
     -CFA  (Common femoral artery) 
     -PROFUN  (Profunda) 
     -LTCIR  (Lateral circumflex) 
     -SFA  (Superficial femoral artery) 
     -POP  (Popliteal artery) 
     -ATA   (Anterior tibial artery ) 
     -PERON  (Peroneal artery) 
    -PTA  (Posterior tibial artery) 
    -DRPED  (Dorsalis pedis) 
l .Vascular Worksheet 
    -Patient information 
    -Measurement Values information 
    -Calculation information 
    %DIA REDUCTION, 
    %AREA REDUCITON, 
     RI, 
     PI, 
    S/D 
     FV 
    REGULAR DIAM 
    REDUCED DIAM 
    REGULAR AREA 
    REDUCED AREA 
    PK SYSTOLICV 
    END DIASTOLICV 
    MEAN 
    VELOCITY 
 
Urologic Measurements & Calculations 
 Left Kidney 
 Right Kidney 
 L-Renal Cortex 
 R-Renal Cortex 
 L-AG 
 R-AG 
l Urology B mode measurement 
    -Bladder Volume  (D1,D2,D3) 
    -Resdual Urine (Area Height) 
    -Whole Gland Prostate Volume     (D1,D2,D3) 
    -Transitional Zone Prostate Volume  (DA,DB,DC) 
l .L-SV 
l .R-SV 
l .L-Ts 
l .R-Ts 
 
l  .Urology worksheet 
    -Patient information 
    -Measurement Values information 
    -Calculation information 
      Bladder Volume 
      Prostate Volume 
      Transition Zone Volume 
      Predicted PSA Level by whole gland volume, 
      Predicted PSA Level by Transitional Zone Volume 
      Prostate Specific Antigen Density 
 
Pediatric Measurements & Calculations 
 
     -Hip 
 
       System Setup 
 
l .Diagnostic Categories: abdomen,  gynecology,   obstetric,  cardiology,  small  parts, carotid, thyroid, 3D, kidney, and musculoskeletal, etc. (Depend on the probe) 
  .User Programmable Preset Capability 
l.Factory Default Preset Data 
l .Languages setup: English, Chinese 
l .Languages for Manuals: English, Simple Chinese,Spanish,French, Russian 
l .Body Surface Area: Western, Eastern 
l .EFBW:12types 
l .WEI/SAB,Shepard,Hadlock1,Hansmann,Tokyo,Hadlock2,Hadlock3,Hadlock4,Hadloc 
     k5,Shinozuka,Warsof,Campbell, 
l .Chroma B: 13 types 
l .ChromaPW,CW,M:5 types for each 
l .Patient Name and ID 
l .Date format::3types mm/dd/yyyy; yyyy/mm/dd; dd/mm/yyyy 
l .Clip format: System/PC 
l .Print Size:6 steps adjustable 
l .System Boot Up: less than 120 sec 
l .Probe Change: less than2 sec 
l .Sensitivity of the trackball: 1, 2, 3, 4,5,6 
 
 Transducers 
Transducer Selection 
l .Four transducer ports 
 
 
 Inputs & Outputs 
l .Audio Stereo Output 
l .Video Out 
    -VGA signal*2 
    -Video output (NTSC or PAL ) 
    -S-Video output (NTSC or PAL ) 
l .Connectors 
    -Remote for B/W Printer or Color Printer 
    -USB: 6 Ports 
    -LAN (DICOM port) 
    -Power for Peripherals 
    -Foot Switch*2 
 
     Operating  Conditions 
l .Ambient temperature: 10°C to 40°C 
l .Relative humidity: 30% to 85% (no condensation) 
l .Atmospheric pressure: 700 hPa to 1060 hPa 
 
 
      Storage  Conditions 
 
l. Ambient temperature: -5°C to 40°C 
l. Relative humidity: <85% (no condensation) 
l .Atmospheric pressure: 700 hPa to 1060 hPa 
                    
 
       Quality Standards 
 
l .ISO 10993 Biological evaluation of medical devices 
 
        Design    Standards 
l .IEC 60601-1 Electrical medical equipment 
l .IEC 60601-1-1 Electrical medical equipment 
l .IEC 60601-1-2 Electromagnetic compatibility 
l .IEC 60601-1-4 Programmable medical systems 
l .IEC 60601-2-37 Comply with the IEC60601-2-37 
 
Not all features or specifications described in this document may be available in all probes 
and/or modes. 
 
 
 
Packaging & Shipping:
Delivery detail:
1. We ship MY-A029Color DopplerUltrasoundScanner by Sea or air for you.
2. Our  MY-A029 Color Doppler Ultrasound Scanner standard export packing, carton box or wooden case
3. No matter what delivery way, all depending on your actual requirements.

Our Services:

1. For all your inquires about us or our MY-A029 Color Doppler Ultrasound Scanner, we will reply you in detail within 24 hours.
2. We own professional team have professional attitude to recommend products and services, introducing the MY-A029 Color Doppler Ultrasound Scanner for you.
3. The MY-A029 Color Doppler Ultrasound Scanner have one year free warranty, after it is still providing after-sales service;
4. We offer OEM services. You can print your own logo on the MY-A029 Color Doppler Ultrasound Scanner..

5. We have very experienced engineers, can help you better use the MY-A029 Color Doppler Ultrasound Scanner or our other products.

Your satisfaction is our duty! It will be our great honor to serve you. We do hope we can offer you more help in medical field and build the long term business relationship with you.

Welcome to visit our company at any time!
Product name MY-A029 Color Doppler Ultrasound Scanner
Brand name MAYA
Packaging Details Carton box for  MY-A029 Color Doppler Ultrasound Scanner
Delivery Detail Within 15 days after payment receipt
Payment Terms T/T, Western Union, Money Gram
Port Guangzhou
Any questions just send us a inquiry

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now