Name | Qty. | Performance and Parameter |
Import CPI high frequency and high voltage generator | 1 | Power:32KW ; Work frequency:100KHz; Photographing (mAs):500mAs; Photographing kV:40~150kV |
Import Toshiba7242EX tube | 1 | Focus:0.6/1.5mm; Photographing kv:40~125kV; Heat Capacity: 200kHU |
Power-driven photographing shell | 1 | Sickle -Style arm photographing shelf |
Photographing bed | 1 | Photographing shelf and photographing bed: the moving up & down, left & right and rotation of the transverse arm should be steady; The up &d own moving scope of the transverse arm:(65-165)cm±3cm,continuously adjustable; Transverse arm rotation around rotation center(rotate to the safety height):(0~105)°±2°; Screen focus distance:(100-180)cm±5cm, continuously adjustable; |
KODAK single CCD+ CsI image detector |
1 | Photographing size:≥17*15 inch |
Image pixels ≥9 million | ||
Limit space resolution≥3.4 Lp/mm | ||
A/D transfer coefficient: 16bit | ||
Clear cmos automatic exposure software |
1 | For real automatic exposure software system, doctors only need to press down hand brake to finish exposure operation instead of setting exposure parameter manually. |
Image-collecting work station | 1 | Dell work station:AMD 2.5GHz, 1GB RAM, hard disk 320GB, 19 inch liquid crystal detector (1 set),100M network interface, DICOM3.0 interface |
Image collecting and disposing software | 1 | automatic /automatic window width /window level, preset window width / window level, positive and negative image turning, image turning, image rotation, image amplification and roaming, labeling and measuring,splitting, automatic electron cutting, part amplification, recovering original image |
*Edge enhancement": automatically distinguish and analyze image, enhance image edge sharpness. | ||
*Dynamic scope optimization: automatically compress dynamic curve of original images for convenient diagnose. | ||
*High-frequency image enhancement:enhance image contrast,improve detail resolution, obviously improve small images such as bone trabecula's . | ||
* Noise inhibition:automatically filter mixed signal, obviously reduce image noise,improve image signal-to-noise ratio. | ||
Other parts | 1 | Import bucky;import beam limit device;high speed data transmission wire |
Optional | Digital image work station software | |
PACS image storage transmission system | ||
Film printer | ||
Automatic exposure system |