MY-D017 500MA Medical x-ray machine |
Department | Technology parameters | ||||||||||
High voltage generator control table and high voltage transform assemble | Fluoroscopy | Tube currency | 0.3-5mA continuous currency | ||||||||
Tube voltage | 50-110KV continuous voltage | ||||||||||
Radiography | Tube currency | 100-500mA shift | |||||||||
Tube voltage | 45-125KV continuous voltage | ||||||||||
Exposure time | 0.02-5s,23 shift | ||||||||||
Power | Voltage | 380V±10% | |||||||||
Frequency | 50Hz±1Hz | ||||||||||
Capacity | ≥30KVA | ||||||||||
Inner resistance | ≤0.3Ω | ||||||||||
X-ray assembly | Type of x-ray | XD52-30.50/125 | |||||||||
Focus | 1×1.2×2 double focal | ||||||||||
Rated rotate speed of anode | 2800r/min | ||||||||||
Changed beam limited device | Diagnosis table YS09D | Automatic, adjusted field of view | |||||||||
Radiograph table YS11S | Manually adjusted field of view, luminosity≥100LX | ||||||||||
C15 Diagnostic table | Rotate of table | -15°~0°~90°automatic | |||||||||
Moving table | Automatic 700mm distance moving lengthways | ||||||||||
Distance of focal table | 400mm | ||||||||||
High of table | 820mm | ||||||||||
Spot film device | Scope moving | Up and down | 600mm | ||||||||
Left and right | ±100mm | ||||||||||
Forward and backward | 300mm | ||||||||||
Way of locking | Electromagnetism locking | ||||||||||
Radiography item | 5″×7″ | ||||||||||
8″×10″ | |||||||||||
10″×12″ | |||||||||||
11″×14″ | |||||||||||
CDGI Multi function radiography table |
Moving table | Lengthways | ±600mm | Electromagnetism locking | |||||||
Across | ±120mm | ||||||||||
Mobile beam filtration grid | Grid density | 28L/cm | |||||||||
Grid ratio | 8:1 | ||||||||||
Focusing distance | 100cm | ||||||||||
Scope of moving | ≥600mm | ||||||||||
Radiography item | 5″×7″,8″×10″,10″×12″,11″×14″, 12″×15″,14″×14″,14″×17″ |
||||||||||
Distance from surface to film | 75mm | ||||||||||
Height of bed | 700mm | ||||||||||
Moving pillar | ±180°,per 90°orientation, moving lengthways ≥1500mm | ||||||||||
Bulb tube | Rotate the cross arm±180,ascend $ descend 1100mm |
LSJ pillar radiography frame | The scope of ascend and descend | 1450mm | |
The minimum distance from focal spot | 380mm | ||
Radiography item | 8"×10" 10"×12" 11"×14"12"×15" 14"×14" 14"×17" |
||
Fixed beam filtration role | Grid density | 40L/cm | |
Grid radio | 10:1 | ||
Focal distance | 180cm |